Bizator  /  Adverts  /  equipment and materials  /  power engineering equipment  /  electric power stations equipment

Automatic switch A, A, A, A

Offer type: salePublished: 28.02.2015
Price:negotiated
Seller:Roman Grigor'evich
Phones:
Show phone
Write a message
Address:Ukraine, Kharkivs'ka Oblast', Kharkiv

Automatic switch A, A, A available new and warehouse 16A - 160A, 110, 220, 320, 380, 440, 660V circuit breaker A. phone +380679972774. Technical description: circuit breakers A rated current up to 160 And semiconductor, thermal and electromagnetic trips. Circuit breakers A, A, A, A - 2 pole made on the DC and AC (50 Hz, 400) currents. Circuit breakers A, A, A, A - 3 pole, made in alternating current (50 Hz, 400).
Circuit breakers are designed to conduct current in normal mode and at overloads of inadmissible duration, short-circuit and inadmissible voltage reductions, and also for infrequent, up to 30 times a day, operational outages of electric circuits with rated voltage up to 660 V AC frequency 50 and 60 Hz and up to 440 VDC. Circuit breakers AC can also be used to protect and infrequent direct launches asynchronous motors in the category of use AC-3. Circuit breakers are manufactured with semiconductor devices, semiconductor and electromagnetic maximum breakers with thermal and electromagnetic maximum tripping current, only with solenoid maximum tripping current and without maximum tripping current. Circuit breakers can be equipped with breakers zero voltage, independent release, free contacts and an electromagnetic drive. Circuit breakers are available in a fixed version - front, rear and combined attach and pull-out performance.
Technical characteristics of switches:
1. Rated current 160A.
2. Number of poles 2; 3.
3. Rated currents thermal tripping devices 16A, 20A, 25A, AND 31,5, 40A, 50A, 63A, 80A, 100A, 125, 160A, semiconductor devices 32A, 40A, 80A, 160A.
4. Setting the initial triggering current in the zone of overload currents, multiple of rated current thermal release of 1.3, the setting of the initial triggering current in the zone of overload currents, times the rated current of the semiconductor devices is 1,25.
5. Setpoint current of the electromagnetic actuation of the maximum tripping current up to 1600A.
6. Nominal operating the highest breaking capacity, kA: at rated voltage 380V AC 35, at the rated voltage 660V AC 20, at rated voltage 440V DC 100.
7. The wear resistance of the switches is the total number of cycles IN 16000, the number of cycles IN under load 10000.
8. Dimensions (width x height x depth), HH mm.
9. Weight (stationary version) 6.5 kg, with an electromagnetic drive 8,7 kg