Sell ammeters MS ( 150-0-150 A.) at a price of 1980 UAH. ( including VAT ).
Phone (062) 343-95-59,
Tel.: 095-533-76-60
Alexander Vladimirovich.
Technical characteristics of the devices M ( ammeters M, voltmeters M, microammeter M, milliammeter M, millivoltmeters M ).
Devices M with light indicator are part of a unified complex analog signal pin devices ASC.
The devices are used for measuring DC current and voltage, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage. The devices can be used to work in a set of transducers (sensors) SHGs.
The devices are designed for flush mounting on panels and boards fixed installations.
The instruments are the five modifications:
pointing - A;
signal;
three - position contact-To;
pin dip with the right contact - KP;
contact with the left rocker contact CL.
Devices used to work at ambient temperatures from -30 to +50° C and relative humidity up to 90% (at 30° C).
Execution of regular and tropical.
With the direct inclusion of the instrument in the chain of time and reassurance from 3 to 4 seconds beyond measure up 5ua; 5-0-5ua; 10mka; 10-0-10mka; 30MKA; 30-0-30MKA; 50mka. At time calm before 3 seconds beyond measure 50-0-50mka; 100mka; 100-0-100mka; 150mka; 150-0-150mka; 300mka; 300-0-300mka; 500mka; 500-0-500mka; when time calming 1.5 seconds measuring range 1mA; 1-0-1mA, 5mA; 5-0-5mA, 10mA, 10-0-10mA, 20mA, 20-0-20mA, 30mA, 30-0-30mA, 50mA, 50-0-50mA, 100mA, 100-0-100mA, 150mA, 150-0-150mA, 300mA, 300-0-300mA, 500mA, 500-0-500mA and 1A; 1-0-1A; 2A; 2-0-2A; 5A; 5-0-5A.
The device is switched into the circuit with external shunt 75mv and time calming 1.5 seconds beyond measure up to 10A; 10-0-10A, 20A, 20-0-20A, 30A, 30-0-30A, 50A, 50-0-50A, 100A, 100-0-100A, 150A, 150-0-150A, 200A, 200-0-200A, 300A, 300-0-300A, 500A, 500-0-500A, 750A, 750-0-750A and 1kA, 1-0-1kA, 2ka, 2-0-2ka, 3ka, 3-0-3ka; 4ka; 4-0-4ka; 5kA; 5-0-5kA; 6kA; 6-0-6kA.
The voltage drop across the microammeter, milliammeter and ammeter with internal shunts does not exceed 120 mV.
On special order the appliances of the type M1730 on the measuring range from 1 mA and above 10 and above can be manufactured in vertical execution, and also for mounting on panels and boards with specified while. order angle.
At rated current 0.2 mA and the decay time of 4 seconds beyond the measurement instruments 10mV; 10-0-10mV, 20mV; 20-0-20mV; 45mv; 45-0-45mv; 50mV; 50-0-50mV, 1B; 1-0-1B; 1,5; 1,5-0-1.5V, 3V, 3-0-3V; 7.5V; 7,5-0-7,5 Century
At the rated current of 1.0 mA and the decay time of 1.5 sec range measurement 75mv and 75-0-75mv.
At rated current 0.2 mA and the decay time of 2.5 seconds beyond measure 100mV; 100-0-100mV, 200mV, 200-0-200mV, 500mV; 500-0-500mV.
At the rated current of 1.0 mA and the decay time of 1.5 sec range measurement devices 10V; 10-0-10V, 15V, 15-0-15V, 30V, 30-0-30V, 50V; 50-0-50V, 75V, 75-0-75V, 150-0-150V, 250V; 250-0-250V; 400-0-400V, 600V; 600-0-600V.
For microammeter with a limit of measurement 5 µa settling time is determined by the external resistance is not less than 8 ohms.
The main error of the instrument type M is ±1.0%.
Burst tolerance photocontact device device type M1730 is ±1.5%.
Operating position horizontal devices.
The length scale devices 120 mm
Changing readings caused deviation of ambient temperature from normal (within -30 to +50° C) for every 10 degrees does not exceed±0,8% for instruments of accuracy class 1.0 and ±0,4% - for instruments of accuracy class 0.5; under the influence of external magnetic field strength of 400 a/m - not exceed ±0,5%; when the deviation of the device 5° in any direction from the operating position - does not exceed ±1,0% for type instruments M1730.
The output current of the photoconductive devices modifications To, CC and CL varies from 30 μa (max) in the dark state to 250 µa (at least) in an illuminated state when powered from a voltage source 10 and the filament voltage of the illuminator lamp is not more than 5 C.
Weight 1.3 kg; dimensions of the device with the cover plate to adjust the position of filters 160 x 35 x 270 mm, weight 1.4 kg; dimensions bracket 182 x 30 x 230 mm, weight 0,3 kg
The devices have a flat cast aluminum alloy, closed the lid.