The instrument is designed to measure tonometric IOP through the eyelid in the area of sclera for Maklakova under load 10,
A unique method of measuring IOP combines innovative approaches to tonometry eye: transpalpebral (measurement through eyelid and sclera (the dimension in the area of the sclera, and not of the cornea).
The principle of operation of the indicator IGD-02 based on the processing function of the acceleration of the movement of the rod as a result of its free fall and interaction with the elastic surface of the eye through the eyelid - dynamic (ballistic) method dosed mechanical vozdeystviyna eyes.
Advantages of the indicator intraocular pressure diathera:
Fast and safe measurement of intraocular pressure
Convenience procedures for the measurement of IOP measurement can be performed in the seated and supine position
The ease of development of the device
The indication accuracy of the original algorithm process control measurement of IOP helps to avoid errors
The portability and mobility of the device allow to use when working out
The ability to conduct daily monitoring of IOP in the selection of medicines
Applications
ophthalmology (including children)
optometry
General medical practice (family medicine)
neurology
Specifications
The tonometric measurement of intraocular pressure by Maklakova under load 10,
Tolerance assessment boundary values (26 mm RT. Art.)
between normal and high pressure ± 2.0 mm RT.article
One dimension, with not more than 3
The supply voltage, 3
Battery type AAA
Number of measurements on one set of batteries, not less than 1500
Service life, years, not less than 5
Weight, g, not more than 89
Overall dimensions, mm, not more than 174 x 26 x 20
Indications for use
Measurement of IOP during mass population surveys
Primary ophthalmic (optometric) examination for selection of high-risk patients with elevated intraocular pressure
Pediatric ophthalmology - measurement of IOP in children of school age
Monitoring and tracking the dynamics of intraocular pressure in non-ambulatory patients, for example, in burn centers, nursing homes and other
Measurement of intraocular pressure in the presence of contraindications to contact the corneal tonometry:
pathology of the cornea
viral infection
dry eye syndrome
laser refractive intervention on the cornea
allergic reactions
Safe non-invasive daily monitoring of intraocular pressure in the selection of adequate antihypertensive drug treatment
Measurement of intraocular pressure with heavy eyes diseases with changes in the anatomy of the eyeball
Contraindications to the use of
Pathological conditions of the upper eyelid - inflammatory diseases, deformation of the century, scars
Expressed pathology of the sclera and/or the conjunctiva in the measurement
Method of measuring intraocular pressure through the eyelid and the device for its implementation is protected by the Patent of Russia No. 2123798, U.S. Patent N US 6,394,954 B1 and Japan Patent N 3593314