The device registration Drive-250
Price: | 2 500 UAH |
Company: | Interservis |
Seller: | Nikolaj Ivanovich |
Phones: | 096-416-73-20 Show phone |
Address: | Ukraine, Dnipropetrovska Oblast', Dnipropetrovsk |
The devices detecting the DRIVE-250 used for reading from
thermocouples, RTDs (voltage, current), from
resistance strain gages, thermometers radiation to measure,
registration, signaling and regulation of technical parameters
processes (temperature, pressure, level, flow, etc.) at various
stages of production in many industries, such as, for example,
as metallurgy, power, chemical and petrochemical
industry, oil refining, food and many other types
industries that require reliable and accurate
pokazivaushee recording analog devices.
Instruments series DISK-250 are perfectly visible on the scale of the circular type and
led indication state - switching on the appliance, breakage sensor,
exit the monitored parameter is outside the setpoint. Line registration
the continuous process on a chart drive. DRIVE-250 is used as
universal instrument for measuring, recording, alarm and
regulation of the desired setting process. Instruments series DISK-20
distinguished by its simplicity of operation and maintainability in Russian
conditions.
Indicating and recording analog devices series DISK-250
Input signals:
from thermocouples PR (), PP(8), XA(K),HC(L),BP(a-1, a-2, a-3), HH(N);
from RTDs 50P, 100P, 50M, 100M;
- voltage: (0-50), (0-100) mV and (0-10), (0-5);
- current (0-5) and (4-20) mA;
from the strain gages;
from radiation pyrometers.
Dipezona measurements (scale): in the tables below.
Error main:
±0.5% of normalizing values on the testimony and conversion;
±1% of the normalizing value for the registration, regulation and signaling.
Speed: 5 or 16 C.
The speed chart:
- 1 turnover in 6 minutes (only for DRIVE-S);
- 1 turn for 8 or 24 h, 6 or 8 days.
Output regulation:
- three-point contact (two independent setpoint, the output signals DC +24V and-24V, load 500 Ohm);
- three-point contact (two independent setpoint, the relay contacts 220V / 1A AC);
the proportional - integral (one setpoint ratio
proportionality 0,5...20; the time constant of integration 20...2000;
output 0...5 mA, the load is not more than 2000 Ohm);
the proportional - integral pneumatic (single setpoint, pneumatic signal 0,2... 1,0 kgf/cm2 (20... 100 kPa), the transformation is carried out electrical pneumoperitoneum EP-1324).
The device is showing "STEEL": only for DISK-S.
The output device alarm:
two-position device (two independent setpoint, the relay contacts
127 V/0.1 a AC or 30 V/0,2 a DC).
Output devices convert:
- input signal into an output current signal 0-5V or 4-20mA, load not more than 2 and 0.5 K, respectively.
Environmental parameters:
- temperature from +5 to +50°C, humidity up to 80% at 25°C (UHL 4.2 according to GOST 15150-69);
- temperature from +5 to +50° C, humidity up to 98% at 35°C without condensation (About 4.2 according to GOST 15150-69).
Power:
- AC frequency (50±1) or (60±1,2) Hz, the voltage (220 +22/-33) or (240 +24/-36) Century
Power consumption: not more than 25 In*A.
They are used for measuring, recording, signaling and regulation
the process parameters (temperature, pressure, level, flow, and so on)
in metallurgy, power, chemical, petrochemical,
oil refining, food processing, pulp and paper and other industries
industry. All kinds of commonly used input signals from
thermocouples, RTDs, mV, V, mA.
Well visible from afar circular scale.
Led indication:
- activate the device;
- breakage sensor;
out of the monitored parameter is outside of the settings.
Continuous line registration on a chart drive.
Versatility - the measurement, recording, alarm and regulation.
Easy operation and repair.
Size: 320 x 320 x 195 mm
Mounting panel (cutout 304+1.5 x 304+1.5 mm).