Devices XD are designed to measure, record, alarm system (control) pressure, flow, differential, power, traction, level, vacuum and other non-electrical quantities, converted interchangeable primary differential transformer sensors in complex mutual inductance 0-10 or 10-0-10 mH.
Resistance to vozvestil temperature and humidity devices meet:
group B4 according to GOST 12997-84 for microclimatically areas with dry and humid tropical climate.
In terms of resistance to mechanical stress and protection from environmental effects, the instruments are made in standard execution according to GOST 12997-84.
Modification devices CFC-1:
001, 002, 003, 004, 005, 006, 007, 008, 009, 010, 011, 012, 013, 014, 015, 016, 017, 018, 019, 020, 021, 022, 023, 024, 025, 026, 027, 028, 029, 030.
Accuracy class of devices - 1.
Valid basic reduced error of the readings on all levels of scale, expressed as a percentage of normalizing the values of the measured input signal, (+- 1%
The time of passing a pointer across a scale of not more than 5s.
The power circuit device is supplied from an AC power napryazhenii 220 m, 50 Hz (Pribor, izgotovlenie on special order, can be powered from the mains frequency is 60Hz).
The power consumed by the device, is not exceeded 25 vA.
The instruments are made in steel with dimensions ham, Board modification. On the front of the unit is a registration system, the toggle and the alarm "Device enabled" toggle - move chart tape. On the top panel under the hood is the signalling control system, the scale adjustment 0-100% with this error srabatyvaniya signaling devices must not exceed +-1,5% of measured values in relation to the set values of the instrument scale. Climatic modification devices NF4.1 - the temperature at which the device can operate from +5 degrees Celsius to +50 degrees Celsius with humidity less than 80%.
Depending on the modification of the devices may have:
- 2 or 3-pin positional signalling device;
rheostat output device for remote transmission of data on the backup device;
rheostat unit with a 100% proportional band for controllers P, PI, PID ;
rheostat device for DPP ;
rheostat device for use with software control devices (RU) ;
- additionally set the input signal Converter in a uniform current output signal (0-5 mA or 4-20mA).
The performance of the devices, no more than 2.5 seconds. or 5 seconds. depending on the modification;
The width of the ribbon diagram: 100mm
The speed of advancement of the ribbon diagram for the devices selected from a range of -10, 20, 40, 60, 120 mm/h, depending on the modification;
The error rate of advance of the ribbon diagram no more than +0,5%;