DESIGNATION STRUCTURE ELECTROTHERMAL RELAYS RTL - X1 HHH X3 X4 X5 X6 4

RTL - designation of the series.

X1 - Digit designating the rated current of the relay: 1-10-25A; 2-40-80A; 3-100-250A; 4-400A.

HHH Digits indicate the performance of the relay adjustment range current failure in the selection table.

X3 - D - letter code that indicates the execution relay RTL-2061 and RTL-2063 for installation contactors PML-DM, PML-DM

X4 - To - letter code that indicates the execution relay RTL-2053 and RTL-2055 with a degree of protection contact terminals IP20 according to GOST 14255 for installation contactors PML-D.

X5 - M - letter code that indicates the execution of the relay with a degree of protection contact terminals IP20 according to GOST 14255 . No letter s means the performance of the relay with a degree of protection contact terminals IP00.

X6 - Letter characterizing climatic version according to GOST 15150 (O*, O, OM)

4 - Digit, denoting the placement category according to GOST 15150

The selection tables toplovich relay:

 

                        I rated And for PML Type The current range of settings, And The power consumed by a single pole at max current setpoint, Motor power, kW, voltage, 50Hz, 60Hz 220 380 440 500 600 10 RTL 1001(M) 0,10-0,17 2,15 - - - - - RTL 1002(M) 0,16-0,26 2,25 - - - - - RTL 1003(M) 0,24-0,40 2,05 - - - - - RTL 1004(M) of 0.38-0.65 1,99 - - - - - RTL 1005(M) 0,61-1,00 2 - - - 0,37 0,37 RTL 1006(M) 0,95-1,60 2 - 0,37 - 0,75 0,75 RTL 1007(M) 1,50-2,60 1,8 0,37 0,75 0,75 1,1 1,1 RTL 1008(M) 2,40-4,00 1,87 0,75 1,5 1,5 2 1,5 RTL 1010(M) 3,80-6,00 1,84 1,1 2,2 2,2 3 3 RTL 1012(M) 5,50-8,00 1,68 1,8 3 3 4 5,5 RTL 1014(M) 7,00-10,00 1,75 2,2 4 3,7 5,5 7,5 16 RTL 1016(M) 9,50-14,00 3 3 5,5 5,5 7,5 10 RTL 1021(M) 13,00-19,00 3 4 7,5 7,5 10 15 25 RTL 1014(M) 7,00-10,00 1,75 2,2 4 3,7 5,5 7,5 RTL 1016(M) 9,50-14,00 3 3 5,5 5,5 7,5 10 RTL-1021(M) 13,00-19,00 3 4 7,5 7,5 10 15 RTL-1022(M) 18,00-25,00 3 5,5 11 11 15 18,5

 

 

                            I rated And for PML Type The current range of settings, And The power consumed by a single pole at max current setpoint W Motor power, kW, voltage, 50 Hz, 60 Hz 220 380 440 500 660 40
40*
RTL 2053 (M) 23,00-32,00 2,43 7,5 15 15 18,5 22 RTL 2055 (M) 30,00-41,00 3,03 10 18,5 18,5 22 30 RTL 2053 (M,*) 23,00-32,00 2,43 7,5 15 15 18,5 22 RTL 2055 (M,*) 30,00-41,00 3,03 10 18,5 18,5 22 30 63 RTL 2055 (M) 30,00-41,00 3,03 10 18,5 18,5 22 30 RTL 2057 (M) 38,00-52,00 3,3 11 22 25 30 37 RTL 2059 (M) 47,00-PHP 64.00 3,69 15 25 30 37 45 RTL 2061 (M) 54,00-74,00 to 4.38 18,5 30 37 45 55 80
100
RTL 2061 (M, DM) 54,00-74,00 to 4.38 18,5 30 37 45 55 RTL 2063 (M, DM) 63,00-of 86.00 5,62 22 37 45 50 70 RTL 3125 74,00-125,00 2,1 30 59 63 80 110

 

 

                                            I rated And for PML Type The current range of settings, And The power consumed by a single pole at max current setpoint W Motor power, kW, voltage, 50 Hz, 60 Hz 220 380 440 500 660 125 RTL 3125 74,00-125,00 2,1 30 59 63 80 110 160 RTL 3170 102,00-170,00 45 80 90 100 140 250 RTL 3270 165,00-270,00 65 110 110 150 200
                        I rated And for PML Type The current range ustock, And The power consumed by a single pole at max current setpoint W Motor power, kW, voltage, 50Hz, 60Hz 220 380 440 500 660 400 RTL 4410 250,00-410,00 2,1 110 185 230 257 335 RTL 4510 310,00-510,00 140 257 280 315 445