Economical Electrode Boiler (EO) ESG 1/3 kW (60 m2) Rivne, Lutsk
Price: | 2 400 UAH |
Company: | "Klimat-OVK" |
Seller: | Roman Oleksandrovich |
Phones: | +380978643092 Show phone +380639761292 Show phone |
Address: | Ukraine |
Mini boilers in parallel operation of two or more of the electrical installations (the same power) in a single system of water heating area, the amount of heated space increases two or more times (example: two modifications 3/36 heat an area of 1500 sqm, 4500 cubic meters; three modifications 3/36 heated area 2250 sq. m., 6750 cubic meters, etc.).
ESG is suitable for different types of water heating systems and is used as a primary or backup heating.
ADVANTAGES:
1. ESG is applied to the heating element from specsplav, which is based on the latest technologies, because of this, ESG has a high efficiency rating – 98%.
2. One kilowatt of power heats ESG 60 cubic meters (20 square meters).
3. The duration of ESG in the system of water heating from 1 to 8 hours depending on the ambient temperature (automatic operation with sensor-relay of temperature), so when the heating area from 40 to 750 sq. m. electricity consumption per day ranges from 2 to 288 kW/h (depending on the modifications, see table of characteristics).
4. ESG during operation in hot water heating system provides heated coolant rise to a height of from 3 to 24 meters (depending on modification), due to the large temperature difference at the inlet and outlet of the electrical installation that allows you to heat a single story and multistory buildings without the use of circulation pumps.
5. ESG is suitable for different types of water heating systems.
6. Entry and exit ESC is mounted in the water heating system through plumbing couplings, plumbing adaptors plumbing or hoses. Input ESG is mounted in the return line, and the output feed line of the water heating system.
7. In a water heating system where is already installed a boiler (boilers), ESG is mounted parallel to the boiler (boilers).
8. In the system water heating with forced circulation of the circulation pump is mounted in return line hot-water heating systems before installation.
9. All work on the electrical installation in hot-water heating system are the same as with conventional electric boilers, gas boilers, ovens, etc.
10. The temperature at the outlet of the electrical installation: up to 95 °C.
11. Working medium (heating medium): water and antifreeze liquid for water heating systems.
12. Working voltage: 220/380 V ± 10%.
13. Length (single phase option): 300 mm.
14. Connection sizes: inlet G1", G1¼".
15. Length (three phase option): 400 mm.
16. Connection sizes: inlet G1¼" G1¼".
Supplied with ESG include:
1. Electrical installation (ESG) — 1 PC.
2. The gage-relay of temperature (thermostat) — 1 PC.
3. Passport (manual) — 1 PC.
4. Individual box — 1 PC.