Operator that does the operation of the industrial facility is constantly engaged his diagnosis available methods tracking: temperature mode (maximum heating), sound support (noise, rattles, rings, or Vice versa quiet), vibration impact (shakes or works), the presence of odors and so next. Based on the availability of certain signs, the assumption of a normal or abnormal operation of the object ...

Pursuing the same analogy with medical diagnostics, You must know what analysis is required for almost all the disease - a common blood test!

If you consider industrial equipment, you usually it is the oil analysis from oil to all moving parts. There are many solutions the main thing is first to formulate the task itself. Most often mechanics interested in what need oil change? The thing is that manufacturers of both equipment and oil can't provide definitive guidance regarding the service life and replacement is necessary and give very average data. You are confronted daily with similar statistics. Give the answer first questions to clarify the concept of "average value":

How often should I change the oil in the engine car?

M ASLO in the engine changes once in 10-15 thousand mileage cars. Notice regarding oils one digit different from the other on 33%! In other words, between the two substitutions, the error will be more than 60%!

One is tempted the conclusion is that, on average, cannot be adopted as the standard! Different duration, conditions and modes of operation, different climate and weather conditions, the variable part are filled with oils even if the label canisters written one and also (there is oils constant formula!). So repeating the question time oil change - response only on the results of the diagnosis!

There are a large number manufacturers macroanalytical: the most famous in Russia is BALTECH and the company "ISI", of the brands I would like to highlight the American company Spectro Scientific (USA Boston) , which has swallowed many other companies, including even one of the branches Emerson !

Indeed, the diagnosis of equipment using masalaboar Spectro Scientific provides the most complete results. And despite the fact that they are cheap, have great the demand for the Russian enterprises.

The interests of the company at Spectro Scientific The Russian market is an exclusive distributor and licensed service educational cents - the Baltech St. Petersburg. Diagnosis equipment with masalaboar Spectro Scientific is for three areas that have different depths of analysis, answering the question that we can be interested in:

1) only Interested in the suitability of oil for further use and the need to confirm replacement? This is the cheapest option of masalaboar!

2) And there is a need the definition of "cause" caused the deviation of the physico-chemical properties of the oil from the control sample (note, not from GOST or ASTM , as this again will be a great averaging)?

Macroanalytical this group will have more expensive but however, they can be used for input control the quality of the oil comparing with the characteristics of the reference model. Removed the infrared spectrum of the oil is like a "fingerprint" and compares with others "fingerprint". Also, "the thickness and pattern of lines," which examines the chemistry of oil including acid number ( TAN) characterizes the residual RES in the RS oil base number ( TBN ) - the presence of active additives, watering oil ( Water ppm ,%) - availability of water in the engine oil it is unacceptable brakowalo the value of 0.2%, and the presence of 0 , 5% water will create an explosive mixture, then examines the degree of nitration, the sulfonation, the presence of soot and glycol and, of course, analyze the viscosity oil.

But you have to understand that just a replacement oil, through the fact that it's the bypass or the viscosity does not correspond to regulatory class - not always solves the problem! For example, oil change not solve the problem if the cause of his watering is worn out seal, through which gets wet.

3) there is Also the direction of the diagnostic equipment through masalaboar with Spectro Scientific oil analysis. In other words, analyses of the share of depreciation present in the oil, and on this basis determined the degree of its wear and the need for repair or replacement of some parts.