Bizator  /  Adverts  /  equipment and materials  /  industrial equipment  /  mining and quarry equipment

Oil and gas equipment

Offer type: salePublished: 27.02.2015
Price:negotiated
Company:OOO 'FIRMA KONTRAGENT'. Ukraina, g. Har'kov
Seller:Sergej Vladimirovich
Phones:
Show phone
Write a message
Address:Ukraine, Kharkivs'ka Oblast', Kharkiv

More: http://contragent.com.ua/produktsiya/category/neftegaz
so 38 (057) 780-96-49; (057) 707-84-38;
(066) 407-97-44;
info@contragent.com.ua;
LLC "FIRM CONTRACTOR. , Kharkov


Tank equipment. Delivery. Installation

TANK EQUIPMENT

Name
Designation

Firing fuses
OP-50,-100,-150,-200,-250,-300

The combined mechanical breather valves
SMDK-50,-100

The valves are not primernaya 2 respiratory membrane
NDCM-100,-150,-200,-250

Valves hydraulic fuses
CNG-100,-150,-200,-250

Crackers cast iron with bypass without bypass
CP-80,-150,-250,-400,-600

The foam generators
GPS-2000

Luke measuring
LPA-50,-80,-100,-150


For purchase please contact the sales pipeline valves
on t/f: (044) 464-93-07, 464-93-08, 230-60-47, 461- 81- 29 or E-mail: 2306047@mail.ru

Of great importance to ensure reliable operation of steel vertical tanks, reduce the loss of oil and oil products from evaporation is the use of a working tank equipment, its correct installation and operation.

The peculiarity of steel tanks is to increase the pressure in the gas space from the evaporation of petroleum products during storage and filling, as well as the increase of vacuum cooling and emptying of the tank.

In the event of a malfunction of the respiratory valve when the pressure in the gas space in the upper zone and in the roof of vertical steel tanks are often formed wypociny, and sometimes breaks. In case of significant vacuum in the upper zones of the body, ceilings and roof decks are created considerable stress, which can lead to the destruction of the roof vertical tank.

Fire tanks
Fire water storage tanks used for fire fighting. These water tanks are referred to the fire water supply system. They are designed for storing regulated supply of water used to extinguish fires. The tanks are mounted on the Foundation. The total number of water tanks in a single node should not be less than two. When you turn off one of the fire capacity in the rest must remain at least 50% fire and emergency water volumes. This means that when there is a malfunction or repair of one of the tanks in the remaining second fire tank should be at least half the total stock of water. As fire water tanks can be used metal containers required volume - horizontal and vertical. When the water tanks are often treated anti-corrosion coating that prevents corrosion of the metal. Also water tanks covered with insulation to prevent freezing of water in freezing temperatures.



Fuse fire (100, 200, 500 pn 0.6 MPa; 500 pn 1.6 MPa)


Fuse fire (in the future PN16) TU U 24607422.007-2000 is designed to prevent the entry of sparks and flame from one area of the pipeline to another during the passage through it of flammable liquids (flammable liquids or their vapors and combustible gases at an operating pressure not exceeding 1.6 MPa (16 kgf/cm2). Fire the fuse is installed at the end or anywhere in the pipeline. Position shooting guard and direction of movement through it of flammable liquids and their vapors, or combustible gases - any. The installation location of the fuse is determined by the design documentation.

The combined mechanical breather valve (SMDK-50, 100)


Combined mechanical breathing valve with safety catch fire (cassette) TU U 24607422.004-99 is intended to regulate the pressure in the gas cavity of the tank, where the oil or oil products, and also for protection from falling sparks and flame into the tank. The appearance of the valve body shown in Fig. The contact surfaces of the valve seat and valve made of PTFE.

Disc reflector to the valves NDCM (150, 200, 250, 350)


Disc reflector is designed to reduce losses of petroleum products in large and small breaths tanks. Drive-reflector is mounted on the flange established between with a flame arrester or respiratory valve and pipe on the roof of the tank. Drives-reflectors are available for pipes with bushing diameters: 150, 200, 250, 350 mm

Disc reflector to CNG valves (150, 200, 250, 350)


Disc reflector is designed to reduce losses of petroleum products in large and small breaths tanks. Drive-reflector is mounted on the flange established between with a flame arrester or respiratory valve and pipe on the roof of the tank. Drives-reflectors are available for pipes with bushing diameters: 150, 200, 250, 350 mm

Crackers crackers with bypass (CP-250, 400, 600)


Crackers TU 24607422.008-2000 is designed to prevent oil spills from land-based tank in case of failure of the valve or pipeline. To open the cover firecrackers used the control mechanism with manual or electric drive (MU, MU, MUSES, MSY).

Luke metering (LPA-80, 150)


Luke measuring LZ-80, -150 TOO.012-2000 is designed for through him measuring the level of oil, produced water and sampling of petroleum products from storage tanks of all types. Luke metering is installed according to the design documentation on the pipe roof vertical tank or pipe cap horizontal tank. The operating temperature of the hatch metering: from minus 40° to plus 60°C.

The foam generator, the average multiplicity (GPS-600, 2000)