котел Saunier Duval THEMA CLASSIC C 25 UN UA
Offer type: salePublished: 28.02.2015
Saunier Duval ThemaClassic C 25 UN UA
0010006165
One of the most popular in Europe, Combi boiler Saunier Duval ThemaClassic C 25 with an open combustion chamber, a power 24,6 kW, electric ignition. Designed for heating, i.e., to ensure the needs for hot water and space heating, equipped with water heating systems and water supply
A method of burning fuel - Open combustion chamber
Min. / max, useful thermal power (heat output), kW - 8,4 - 23,6
Efficiency at 100% power, % - 91,8
Noise level, DB (a) - Up to 55
Gas
Kind and type of fuel (natural gas / LPG) - 20 G/G 31
The gas inlet pressure natural // liquefied, mbar - 20/37
The gas pressure at the inlet to the burner after the valve: min / max, natural gas mbar - 2,16-12,55
The gas flow rate min / max, natural gas, m3/HR - 1,07-2,77
The diameter of the injector (natural gas /liquefied gas), mm - 1,2/0,73
Heating circuit
Max, the temperature of the water in the heating system, °C - 87
The range regulated. temperatures in the system. heating, °C - 87-38
Min. / max water pressure in the heating system, bar - 0,8/3
The capacity of the pressurizer, l - 5
Max, the volume of water in the heating system with built-in pressurizer, l - 110
The DHW circuit
Max water temperature in the DHW system, °C - 63
The control range of the DHW temperature, °C - 38-63
Min. / max water pressure at the inlet, bar - 0,5/10
Min. the flow of hot water through the boiler, l/min to 1.7
Max, the flow of hot water at t =30°C l/min - 11,3
Electricity
Nom voltage / frequency, V/Hz 230/50
Nominal current consumption, And to 0.3
Max, power consumption, W - 70
Class of protection against electric shock El.Current / degree of protection from the influence of moisture - 1/Px4D
The combustion parameters
The temperature of the combustion products at the exit of the apparatus at a max heat output, S - 118
Air consumption at max output, m3/h 57
The flow rate of the flue gas, Gr/sec - 20,7
The concentration of CO at max output, ppm - 20
The concentration of C02 to the max, output, % - 4,85
NOx at 0% 02 at max output, ppm - 73
The class of apparatus for NOx - 3
The dimensions of the boiler
Dimensions: width x depth x height, mm - 410x311x742
Fitting gas, inch - 3/4
Fitting the heating circuit, inch - 3/4
Fitting the DHW circuit, inch - 1/2
The diameter of the chimney, mm - 125
The weight of the boiler, kg - 31
Saunier Duval boiler ThemaClassic C 25 can provide hot water to 11.3 liters per minute at DT=30 °C, and heat conditional area of about 230 m2.
Gas boiler automatics has high sensitivity and enables to operate at low gas pressure.
The boiler has the opportunity to work on natural and liquefied gas. To convert the boiler to work on liquefied gas, it is necessary to replace the nozzle and the gas valve.
Equipment boiler Saunier Duval Thema Classic C 25
gas atmospheric burner block ignition and flame control,
gas valve with modulating stepper drive, providing precise control and small dimensions, with the safety valve of the gas block (EVS), which cuts off the gas supply in emergency situations,
primary copper heat exchanger,
steel DHW plate heat exchanger,
mechanical filters built into hydrograph,
single-speed pump,
expansion tank,
the pressure sensor,
the three-way valve with actuator,
relief valve,
automatic air bleeder,
built-in adjustable bypass,
built-in manual valve for feeding the heating system with a check valve,
fan (boilers sealed combustion chamber),
control panel with LEDs and LCD display
control Board with built-in microprocessor.
Safety devices and protective functions of the boiler:
relief valve,
the pressure sensor coolant
emergency temperature sensor,
the sensor DHW flow with an improved protection system from clogging and fouling,
thermostat thrust (in boilers with an open combustion chamber),
manostat thrust (in boilers sealed combustion chamber),
function heat antinelli (run-on pump),
function antitelephone pump,
the antifreeze function of the boiler,
function anticyclical boiler,
the start-up delay mode DHW,
the function of maintaining a predetermined temperature DHW,
the function of cutting off the gas supply, the safety valve of the gas block.
In case of a power outage boiler turns off and when the utility power will be incorporated in the work, keeping all presets.
The boiler has the ability to adjust the power of the heating system, depending on needs without changing the maximum power for hot water systems.
The boiler can be connected:
room thermostat (simple or programmable);
the chimney damper with actuator;
the ambient temperature sensor;
both sensors simultaneously. Thus, the operation of the boiler is carried