Bizator  /  Adverts  /  equipment and materials  /  industrial equipment  /  heating engineering, boilers

boiler+pipe Saunier Duval THEMA CLASSIC F 25 UN UA

Offer type: salePublished: 28.02.2015
Price:634 EUR
Company:Nikolaj
Seller:Nikolaj Kolesnichenko Vladimirovich
Phones:
Show phone
Write a message
Address:Ukraine
Saunier Duval ThemaClassic F 25 UN UA 0010006166 One of the most popular in Europe, Combi boiler Saunier Duval ThemaClassic F 25 with closed combustion chamber, with a capacity of 24 kW, electric ignition. Designed for heating, namely to ensure the needs for hot water and space heating, equipped with water heating systems and water supply. Saunier Duval boiler ThemaClassic F 25 can provide hot water to 11.3 liters per minute at DT=30 °C, and heat conditional area of about 230 m2. Gas boiler automatics has high sensitivity and enables to operate at low gas pressure. The boiler has the opportunity to work on natural and liquefied gas. To convert the boiler to work on liquefied gas, it is necessary to replace the nozzle and the gas valve. Equipment boiler Themaclassic F 25: gas atmospheric burner block ignition and flame control, gas valve with modulating stepper drive, providing precise control and small dimensions, with the safety valve of the gas block (EVS), which cuts off the gas supply in emergency situations, primary copper heat exchanger, steel DHW plate heat exchanger, mechanical filters built into hydrograph, single-speed pump, expansion tank, the pressure sensor, the three-way valve with actuator, relief valve, automatic air bleeder, built-in adjustable bypass, built-in manual valve for feeding the heating system with a check valve, fan (boilers sealed combustion chamber), control panel with LEDs and LCD display control Board with built-in microprocessor. Safety devices and protective functions of the boiler: relief valve, the pressure sensor coolant emergency temperature sensor, the sensor DHW flow with an improved protection system from clogging and fouling, thermostat thrust (in boilers with an open combustion chamber), manostat thrust (in boilers sealed combustion chamber), function heat antinelli (run-on pump), function antitelephone pump, the antifreeze function of the boiler, function anticyclical boiler, the start-up delay mode DHW, the function of maintaining a predetermined temperature DHW, the function of cutting off the gas supply, the safety valve of the gas block. In case of a power outage boiler turns off and when the utility power will be incorporated in the work, keeping all presets. The boiler has the ability to adjust the power of the heating system, depending on needs without changing the maximum power for hot water systems. The boiler can be connected: room thermostat (simple or programmable); the chimney damper with actuator; the ambient temperature sensor; both sensors simultaneously. Thus, the operation of the boiler is carried out with equivalent thermal regulation and adjustment room thermostat; clock; device "DIACOM" deep diagnostics of boiler services. A method of burning fuel is a Closed (sealed) combustion chamber Min. / max, useful thermal power (heat output), kW - 8,9 - 23,6 Efficiency at 100% power, % - 91,5 Noise level, DB (a) - Up to 55 Gas Kind and type of fuel (natural gas / LPG) - 20 G/G 31 The gas inlet pressure natural // liquefied, mbar - 20/37 The gas pressure at the inlet to the burner after the valve: min / max, natural gas mbar - 2,25-12,2 The gas flow rate min / max, natural gas, m3/HR - 1,16-2,74 The diameter of the injector (natural gas /liquefied gas), mm - 1,2/0,73 Heating circuit Max, the temperature of the water in the heating system, °C - 87 The range regulated. temperatures in the system. heating, °C - 87-38 Min. / max water pressure in the heating system, bar - 0,8/3 The capacity of the pressurizer, l - 5 Max, the volume of water in the heating system with built-in pressurizer, l - 110 The DHW circuit Max water temperature in the DHW system, °C - 63 The control range of the DHW temperature, °C - 40-63 Min. / max water pressure at the inlet, bar - 0,5/10 Min. the flow of hot water through the boiler, l/min to 1.7 Max, the flow of hot water at t =30°C l/min - 11,3 Electricity Rated voltage / frequency, V/Hz 230/50 Rated input current, a - 0,53 Max, power consumption, W - 122 Class of protection against electric shock El.Current / degree of protection from the influence of moisture - 1/IPx4D The combustion parameters The temperature of the combustion products at the exit of the apparatus at a max heat output, S - 160 Air consumption at max output, m3/h 44 The flow of flue gas emissions, G/s - 15 The concentration of CO at max output, ppm - 60 The concentration of C02 to the max, output, % - 6,7 NOx at 0% 02 at max output, ppm - 65 The class of apparatus for NOx - 3 The dimensions of the boiler Dimensions: width: