Bizator  /  Adverts  /  equipment and materials  /  power engineering equipment  /  electric power stations equipment

The VLF 40 + HADES

Offer type: salePublished: 27.10.2017
Price:negotiated
Company:OOO 'Dneproenergotehnologii'
Seller:Vladimir Evgen'evich
Phones:
Show phone
Write a message
Address:Dnipropetrovska Oblast', Dnipropetrovsk, Ukraine

Installing a subwoofer 40 + HADES

Installation of high voltage for testing solid dielectrics.

 

The purpose of the position:

 

1. For testing of medium voltage cables working stress

6,10,15,20 (kV), all types, oil-paper insulation and isolation from cross-linked polyethylene.

2. to check the cable sheath.

3. to test insulators and other electrical variable high voltage power frequency voltage.

4. for laboratory work and research.

Features: installation completed block that provides convenience in transportation and use.

For example, when testing insulators transformer substations there is only one high-voltage unit, without the switching unit.

The kit includes a convenient and flexible transport trolley.

 

Technical data

General information:

1. Supply voltage AC, --- 220±10%(50Hz).

2. Maximum current consumption, And, not more than ----- 5.

3. Ambient temperature ---------------- -10...+45 °C.

4. Storage temperature ------------------------- -20...+45 °C.

5. Relative humidity at temperature+25 ° C, %, not more ----------------------------- 80.

6. Atmospheric pressure, mm RT. Art.--------------- from 630 to 800.

7. Total weight with regard to the transport truck, kg, no more -- 115.

8. The mode of operation is continuous, not less than Jn.

9. Average time service, years--------------------- 10.

Output voltage:

10. The maximum voltage in operating mode generator low frequency, cosine-rectangular (squarewave) form------------ 40.

11. Three fixed frequency generator, subwoofer, (Hz)------- 0,1; 0,05; 0,02.

12. The maximum voltage in operating mode DC rectified voltage + ∕ - , (kV) ------------------------ 40.

13. The maximum voltage in operating mode generator AC sinusoidal voltage of frequency 50 (Hz) (kV) ------------- 50.

14. Maximum loading capacity when running installation in the generator mode VLF frequency: 0.1 Hz----------------------------- 0,3 (ICF);

                                      0.05 Hz----------------------------- 0,6 (ICF);

                                      0.02 Hz----------------------------- 1,5 (ICF).

15. The accuracy of the measurement of the output voltage, (%) -------- 3.

16. The resolution of the measurement of the output voltage, (Century)----- 100.

Output current:

17. The maximum current setting in all modes (mA)----- 14.

18. Two ranges measure the output current 1 ∕ 20 (mA).

19. The accuracy of the measurement of the output current (%) -------------- 3.

Optional:

Built-in timer at three fixed time intervals, 1 min., 5min., 30min., function real-time clock. When reaching the time installation automatically turns off the test mode, with sound and light indication.

 

 

The warranty period is 1 year.
Number of deliveries: any.

http://det-etl.n4.biz, http://det.zakupka.com, http://det.infobiz.in.ua

http://dneproenergotehnologii.pul.ru, http://dneproenergo.uaprom.net

+38 (095) 601-35-90, (056) 788-51-01, (092) 788-51-01

SKYPE: energo-CL