Bizator  /  Adverts  /  equipment and materials  /  power engineering equipment  /  cable-conducting products

Wire IDC 3x2.5, buy Wire IDC 3x2.5 Kiev

Offer type: salePublished: 27.02.2015
Price:10.35 UAH
Company:Kabel'naya produktsiya
Seller:Menedzher pvs-shvvp-pv
Phones:
Show phone
Write a message
Address:Kyiv, Ukraine
Description Wire connector IDC 3x2.5

The flexible connecting wires with stranded copper conductors with PVC insulation, PVC sheathed; PVA e - screen of copper wires.

Cable construction :

Conductor - copper, round shape, multi-stranded class 5 flexible. Insulation - PVC plastic.

Twisting - the insulated cores are twisted without filler. The insulated cores patriliny wires are allowed to twist around the core.

Shell PVA, PSA - PVC plastic; in the wires Psnh plastic, flame retardant. Shell in the wires superimposed with the filling of the spaces between the veins, giving the wire a round shape.

The screen Pwsa made in the form of a braid of copper wires or aluminum foil.

Scope PVA 3x2.5:

Wire IDC 3x2.5 is intended for connection of electrical appliances, power tools, small tools, other machines and appliances (washing machines, refrigerators and so on) for voltages up to 380 V for systems 380/660 Century for the manufacture of extension cords. PSA is designed to connect electrical installations operating in critical industrial electromagnetic environment in places where required a high degree of noise immunity from external interference, in the technique of measurement, monitoring, control and regulation, in dry and wet conditions. Wire PVA, Pwsa are burning with only one layer. Wire Psnh are burning when they are laid in bunches.

Specifications PVA 3x2.5:

The operating temperature range from -25°C to +40°C

Relative air humidity at temperatures up to +35°C up to 98%

Resource wires, expressed in resistance to repeated bending,

when the rated voltage is not less than 30000 cycles (60000) (movements)

Rated frequency 50 Hz

The density of the braid PSA and Pushing 62%

AC voltage test, 50 Hz: 2 kV

The long-term allowable temperature of the heating wires of the cables during operation +70°C