Sell ammeters MS ( 150-0-150 A.).

Phone (062) 343-95-59,

Tel.: 095-533-76-60.


The DATASHEET.

Technical characteristics of the devices M ( ammeters M, voltmeters M, microammeter M, milliammeter M, millivoltmeters M ).

 

 

     Devices with M light indicator are part of a unified complex analog signal pin devices ASA.

     The devices are for measuring DC current and voltage, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage. The devices can be used to work in a set of transducers (sensors) SHGs.

     Devices designed for flush mounting on panels and boards fixed installations.

     Devices are the five modifications:

     pointing - A;

     signaling - With;

     contact three-position - To;

     contact off with the right contact - KP;

     contact dip with the left contact - CL.

     Devices used to work at ambient temperatures from -30 to +50° C and relative humidity up to 90% (at 30° C).

     Performance regular and tropical.

 

     When the direct inclusion of the instrument in the chain of time and reassurance from 3 to 4 seconds measurement limits are 5ua; 5-0-5ua; 10mka; 10-0-10mka; 30MKA; 30-0-30MKA; 50mka. At time calm before 3 seconds beyond measure 50-0-50mka; 100mka; 100-0-100mka; 150mka; 150-0-150mka; 300mka; 300-0-300mka; 500mka; 500-0-500mka; when time calming 1.5 seconds measuring range 1mA; 1-0-1mA, 5mA; 5-0-5mA; 10mA; 10-0-10mA, 20mA, 20-0-20mA, 30mA, 30-0-30mA, 50mA, 50-0-50mA, 100mA, 100-0-100mA, 150mA, 150-0-150mA, 300mA, 300-0-300mA, 500mA, 500-0-500mA and 1A; 1-0-1A; 2A; 2-0-2A; 5A; 5-0-5A.

     When turned on device in circuit with external shunt 75mv and the decay time of 1.5 sec range measure up to 10A; 10-0-10A, 20A, 20-0-20A, 30A, 30-0-30A, 50A, 50-0-50A, 100A, 100-0-100A, 150A, 150-0-150A, 200A, 200-0-200A, 300A, 300-0-300A, 500A, 500-0-500A, 750A, 750-0-750A and 1kA, 1-0-1kA, 2ka, 2-0-2ka, 3ka, 3-0-3ka; 4ka; 4-0-4ka; 5kA; 5-0-5kA; 6kA; 6-0-6kA.

     Fall the voltage on the microammeter, milliammeter and ammeter with internal shunts does not exceed 120 mV.

     Special order devices of the type M1730 on the measuring range from 1 mA and above 10 and above can be manufactured in vertical execution, and also for mounting on panels and the boards agreed with. order angle.

     At rated the current 0.2 mA and the decay time of 4 seconds beyond the measurement instruments 10mV; 10-0-10mV, 20mV; 20-0-20mV; 45mv; 45-0-45mv; 50mV; 50-0-50mV, 1B; 1-0-1V, 1.5V; 1,5-0-1.5V, 3V, 3-0-3V; 7.5V; 7,5-0-7,5 Century

     At rated the current of 1.0 mA and the decay time of 1.5 sec range measurement 75mv and 75-0-75mv.

     At rated the current 0.2 mA and the decay time of 2.5 seconds beyond measure 100mV; 100-0-100mV; 200mV; 200-0-200mV, 500mV; 500-0-500mV.

     At rated the current of 1.0 mA and the decay time of 1.5 sec range measurement devices 10V; 10-0-10V, 15V, 15-0-15V, 30V, 30-0-30V, 50V; 50-0-50V, 75V, 75-0-75V, 150-0-150V, 250V; 250-0-250V; 400-0-400V, 600V; 600-0-600V.

     For ammeter with a limit of measurement 5 µa settling time is determined by the external resistance is not less than 8 ohms.

     The main the error of the instrument type M is ±1.0%.

     Error actuation photocontact device device type M1730 is ±1.5%.

     Working position horizontal devices.

     The length scale devices 120 mm

     Change the readings caused deviation of ambient temperature from normal (within -30 to +50° C) for every 10 degrees does not exceed±0,8% for instruments of accuracy class 1.0 and ±0,4% - for instruments of accuracy class 0.5; under the influence of external magnetic field strength of 400 a/m - not more than ±0,5%; when the deviation of the device 5° in any direction from the operating position - does not exceed ±1,0% for type instruments M1730.

     Output current of photoconductive devices modifications To, CC and CL varies from 30 μa (not more) in a dark state to 250 µa (at least) in an illuminated state when powered from a voltage source 10 and the filament voltage of the lamp fixture is not more than 5 C.

     Weight 1.3 kg; dimensions of the device with plate to adjust the position of filters 160 x 35 x 270 mm, weight 1.4 kg; dimensions bracket 182 x 30 x 230 mm, weight 0,3 kg

     The devices have a flat cast aluminum alloy housing, closed the lid.