Stopwatch SETS-S (SACS, SEO S, SEEDLING-S, SEEDLING-S, SEEDLING-S, SETS-S, SETS-S, SETS-S)
Designed to measure the time interval indicating the measurement results in digital form.
Measuring ranges:
I band - with up to 99.99, interval (increment count) - 0.01;
II range - to 999.9 withthe scale (readability) - 0.1;
III range - up to s, scale (readability) - 1C.
Input (50-1000 Hz): ±12...40 V, ±36...120V, ±72 240V...
Stopwatches SETS-S designed to measure intervals of time of display of measurement results in digital form.
Stopwatch SETS-S can be used to measure the response time of the electromagnetic relay, AC and DC, the duration of single electrical pulses, the total duration of package electrical impulses, etc.
Conditions of operation of the stopwatch SETS-S:
1) ambient temperature - -10 to 50°C at a rate of change of temperature to 40°C for 8 h;
2) humidity - up to 95% at 35°C and below;
3) atmospheric pressure from 84 kPa (630 mm Hg. calendar) to 106.7 kPa (800 mm Hg. calendar).
Specifications
Maximum scale stopwatch - 9999 S. the Number of measurement ranges - 3:
I range - up to 99.99 s, the interval (increment count) - 0.01;
II range - to 999.9 s, the interval (readability) - 0.1;
III range - up to 9999 with the scale (readability) - 1C.
The transition from band - automatic. Permissible relative error of the stopwatch δ = A/t + B, where A is the maximum systematic error of the stopwatch; t is the measured time interval; - the relative error of the master oscillator. Value And does not exceed the values:
in the I ±0.02;
in the second range of±0.1;
in III ±1C.
Value does not exceed the values:
at a temperature of (23±5)°C - 5·10-5;
at a temperature of from -10 to 50°C - 5/10-5.
Indication - digital four-digit decimal. Work stopwatch SETS-Scan be done in one of three modes:
in manual mode, the buttons on the stopwatch;
in remote mode using the switching devices connected to the external connector on the stopwatch SETS-S;
in the automatic control is by means of an electric signal applied to the measuring inputs of the stopwatch SETS-S.
Normal operation of the stopwatch SETS-S is provided when applying for measuring inputs signals corresponding to the values given in table. 1
Table 1
No. of input
Effective stress
AC input signal,
The frequency of the alternating
the input signal, Hz
Voltage DC input signal,
1
36 +3,6/-4,8
50...1000±12 402...
110 +11/16,5
50...1000±36 1203...
220 +22/-33
50...1000±72 240...
The input impedance of the stopwatch measurement inputs, at least:
input 1 - 0.9 ohms;
input 2 of 4.4 ohms;
input 3 of 9.7 ohms.
The main electrical power to the stopwatch SETS-S is supplied from single-phase AC voltage (220 +22/-33); frequency (50± 1) Hz harmonic distortion less than 5%. The power consumed from the CE Stopwatch SETS-S (SACS, SEO S, SEEDLING-S, SEEDLING-S, SEEDLING-S, SETS-S, SETS-S, SETS-S)
Designed to measure the time interval indicating the measurement results in digital form.
Measuring ranges:
I band - with up to 99.99, interval (increment count) - 0.01;
II range - to 999.9 withthe scale (readability) - 0.1;
III range - up to s, scale (readability) - 1C.
Input (50-1000 Hz): ±12...40 V, ±36...120V, ±72 240V...
Stopwatches SETS-S designed to measure intervals of time of display of measurement results in digital form.