Gas piston power plant tedom 480 kW, new
Offer type: salePublished: 24.04.2015
New GPU, without achievements, container version.
Electrical capacity of 480 kW and thermal 612 kW
Cogeneration unit (hereinafter CU) TEDOM this series belong to the machines of medium and high capacities based on gas engines. KU this series are available with a power range from 40 kW to 200 kW.
The layout of KU in modular design, includes three stand alone unit motor-generator, a complete thermal equipment installation, including exhaust mufflers and electric valves (control and power). KU, as per the technical specifications, designed to operate on natural gas and the location under the open sky. KU performed with synchronous generator for parallel operation with the network: 400V/50 Hz, thermal contours are adapted to the temperature gradient of 90/70°C. KU forms a completely self-contained power unit.
TEDOM cogeneration plant 3 x Cento T160 consists of:
- Special complete insulated container 3 KU 1 PC.
system electric heating
ventilation with louvers at the inlet and the outlet of the container
the lighting system of the container with the outlet 24+220 V
the system of sensors, Instrumentation, recording and alarm system gas leak
the weather protection from snow at the exit of ventilation in the container
fire alarm, visual and audible
fire extinguishing system Firestop
siphon for condensate removal OK only for the alignment of combustion etc.
all necessary internal connecting piping
all necessary internal connection wiring
all the necessary installation and commissioning of installation of the equipment in the container
A reciprocating internal combustion engine TEDOM TV 170 G5V TW 86 3 PCs.
Electric generator 0.4 kV 3 PCs.
Gas route KU (2 - 10 kPa) 3 PCs.
The system of air intake for the internal combustion engine 3 PC.
System to Supplement and replace the lubricating oil 3 PCs.
Auxiliary systems of the engine 3 PC.
separation of oil mist
starting system (battery)
Cooler filling mix 3 PCs.
Emergency cooler 3 PCs (insufficient cooling at the selection of thermal energy or in the production of electric energy)
Muffler exhaust 3 PCs.
The control system of the KU Pro - Con Sight 3 PCs.
Hub T - Con (upstream management of multiple KU, 1 PC. for parallel operation with the network system prepared for 3 CU)
The visualization system, communications and data logging 3 PCs.
Power switchboards 0.4 kV 3 PCs.
Generator protection
Parameter / type KU
Cento T160
the engine
TG 170 G5V TW 86
operating speed
1500/min
the alternator voltage
0.4 kV
nominal electric power
160 kW
the maximum thermal power
204 kW
supplied power fuel
424 kW
K. p. D. electric
37.8% of
K. p. D. heat
48,1 %
K. p. D. General
85,9 %
gas consumption at 100% power
to 44.8 cubic/hour
the calorific value of the fuel
34 MJ/MZ
the size of the container