Dryer with cooler, new
Price: | 80 000 $ |
Seller: | Aleksandr |
Phones: | +380952777776 Show phone |
Address: | Ukraine, Kyiv |
Manufacturer: As-El Mühendislik Tahıl Kurutma Makinaları, Turkey
DRYER model: ASM1,SERIAL NUMBER: 350
GRAIN OLOGICAL model: VLKN2, SERIAL NUMBER: 250
Production year: 2011
Condition: New
City: Kiev
Description and principle of operation:Method heat transfer (drying) by means of hot air. Boxes and parts of the dryer is galvanised. The combination drying with heated air in the dryer and cooling the grain in the cooler ventilation ("Full heat"). In the process of drying, hot air to a predetermined temperature under high the pressure created powerful generators, passing through a uniform a layer of grain as it heats. Formed thus the moisture is removed out through perforated walls of the grain cameras. PID controller Siemens. Dryer designed to work at temperatures from -10 to +40 °C and relative humidity of 95%.
Is used for drying legumes and oilseed crops and is also ideal for drying seed material due to the small minimum drying temperature. Drying sieves suitable for oilseed rape varieties.
Technical characteristics of the dryer:
Dimensions:
Length - 10.20 m
Width – 2.62 m
Height – 4.62 m
Width columns – 0,69 cm
Fans – 2 PCs diameter 1 m. the motor 11 kW - 2 units = 22 kW.
Burners – 2 PCs temperature up to 1000 degrees C.
Average natural gas consumption (upper burner /lower burner) 280м3/h.
Average the consumption of propane-butane (upper burner lower burner) 145 l/h . 80 kg/h.
Top auger – 9 M. 50t/h 5.5 kW.
Lower auger – 9 M. 50t/h 5.5 kW + chain mechanism 1 kW.
Auger download out of the bunker 10 meters 50t/h 7.5 kW.
Capacity - maize 23 tons.
Remote management - automated.
Consumed power = 41.5 kW.
Technical specifications grain chiller:
Dimensions:
Length – 7.50 m
Width – 2.62 m
Height – 4.62 m
Width columns – 0,35 m
Fans - 1 PCs. diameter 1 m. the motor 11 kW.
Top auger – 6,5 M. 50t/h 3,5 kW.
Lower auger 6.5 m 50t/h 3.5 kW + chain mechanism 1 kW.
Auger download from the hopper 7 M. 50t/h 7.5 kW.
Auger download transport in 10 m 50t/h 7.5 kW.
Capacity - corn 11.5 tons.
Consumed the power of 34 kW.
In General: 41,5 kW + 34 kW =75 kW.
RECOMMENDED LEVELS OF GRAIN MOISTURE CONTENT AND DRYING TEMPERATURE:
Culture: Barley, Oats, Rice, Rye, Sorghum.
1. The recommended maximum moisture level of grain when stored in ventilated bunker.
Culture: Barley 13%, Oats 13%, Rice 11%, Рожь13%, Soroko 14%.
2. The maximum drying temperature for: a) seed (F)/(C)
Barley, Oats, Rice, Rye, Soroko °F110 /43 °C
b) forage grain (F)/(C)
Barley (160 °F/71 °C), Oats (160 °F/71 °C), Rice (140°F/60 °C), Sarago (180°F/82 °C), Rye (190°F/87 °C).
Culture: Soybean/Rapeseed, Sunflower, Wheat, White corn, Yellow corn.
1. The recommended maximum moisture level of grain when stored in ventilated bunker.
Culture: Soybean/Rapeseed 13%, Sunflower 10%, Wheat 13%, White maize by 14%, Yellow corn 14%.
2. The maximum drying temperature for: a) seed (F)/(C)
Soybean/Rapeseed, Sunflower, Wheat, White maize, Yellow maize 110°F /43 °C.
b) forage grain (F)/(C)
Soybean/Rapeseed (71°C /160°F), Sunflower (65°C /150°F), Wheat (87°C /190°F), White corn (99°C /210°F), Yellow corn (110°C /230°F).
Security of operation: the Electronic control unit (SIEMENS) constantly receives data from sensors and internal external temperature, sensor of level of grain in the grain columns, and multiple temperature sensors of hot and cold grain. If you experience any emergency automatics closes the fuel supply to the burner and performs emergency shutdown of the power systems of the dryer.
Easy to clean dryers: adjustable dampers and auxiliary hatches provide easy access for manual cleaning of columns.
Performance:
• Performance 50 t/h
• Drive the auger by means of a motor.
• Height overload up to 6 m.
• High performance thanks to the continuous supply of grain through the auger.
The gas system of the dryer is from the main gas system burner and gas burner system. At the entrance to the gas system is shut-off ball valve and angle the filter sump. In the composition of the gas system pilot burner in addition to pipes and fittings include pressure gauge, the solenoid valve and lowering valve.
The composition of the gas main burner system includes: • step-down the regulator valve; • automatic switch low pressure; shut-off valve with manual control manufactured by Siemens; • electromagnetic valve of ventilation gas system; • automatic switch of high pressure; • electromagnetic the valve is gradual change of a current of gas; • pressure gauges before and after lowering valve; • drain ball valve; • the Main burner manufacturing company.
PID controller Siemens. Controller is a compact controller for a smooth operation without feedback the actuator