Bizator  /  Adverts  /  equipment and materials  /  power engineering equipment  /  electric power stations equipment

Relay control voltage series IO, ATE

Offer type: salePublished: 28.02.2015
Price:negotiated
Company:PAO "Elektrotehnicheskij zavod" (Kiev, torgovaya mar
Seller:Sergej Zagorujko
Phones:
Show phone
Write a message
Address:Ukraine, Kyiv
VOLTAGE RELAY IO-18-1, NL-18-2 Relay IO-18 refer to static relays DC and AC =110, 220 and ~110, 220 V; 50, 60 Hz, without external power supply, with digital readout values of the controlled parameter and programmable by setting the actuation setpoints input affecting value. By the nature of the input changes affecting value are: NL-18-1 - relay maximum voltage; NL-18-2. minimum voltage. Nominal voltage @110 V, @220 C. The supply voltage range: =75...265 V, ~75...265 C. Basic measurement error: 5%. Discrete setpoint voltage: 1 Century The discreteness of times: 1 second Details see: http://relsis.ua/relsis/tree/Products/rele_napryazheniya/tehnicheskoe_opisanie_nl-18.htm VOLTAGE RELAY IO-19 Relay IO-19 refer to static relays DC and AC =110, 220 and ~110, 220 V; 50, 60 Hz, without external power supply, with digital readout values of the controlled parameter and programmable by setting the actuation setpoints input affecting value. By the nature of the input changes affecting the value of the IO-19 relays are the maximum and minimum voltage. Nominal voltage @110 V, @220 C. The supply voltage range: =75...265 V, ~75...265 C. Basic measurement error: 5%. Discrete setpoint voltage: 1 Century The discreteness of times: 1 second Details see: http://relsis.ua/relsis/tree/Products/rele_napryazheniya/tehnicheskoe_opisanie_nl-19.htm RELAYS COMPREHENSIVE PROTECTION THREE-PHASE NETWORK ATE-23 Designed for use in three-phase circuits 3x400/220V (including neutral) and 3x400V to control: - the value of the voltage at two levels within 160-276 In system (3x400/220V) or 280-480 In system (3x400 V); - asymmetry of phases; - phase sequence; - loss phases. Adjustable time delay allows you to ignore transient voltage surges in the circuit. The "Memory" for returning from erroneous in normal mode you need to press the "Reset" button on the front panel of the relay. 2 relay outputs, with selectable functions of the second relay (independent/parallel). The device is resistant to the induction voltage from the rotating equipment that is connected to the second phase. Power: Galvanically isolated power supply: - AC: 400, 220, 24; - DC: 24 Century. The permissible deviations of the supply voltage -15%...+10%. Power supply terminals: A1, A2. Power consumption, not more than: 4,5 VA. Details see: http://relsis.ua/relsis/tree/Products/rele_napryazheniya/tehnicheskoe_opisanie_el-23_el-23n.htm MONITORING RELAYS THREE PHASE VOLTAGE ATE-22N Designed for control voltages in three-phase circuits 3x400/220V (including neutral) and 3x400V (without neutral) with adjustable upper and lower threshold voltage to turn off the relay with adjustable delay time. Power is supplied from the controlled voltage, i.e., from all phases, which allows the relay to operate and with the loss of one of the phases. Adjustable time delay allows you to ignore transient voltage surges in the circuit. Power and control: Power and control: neutral h Century Power supply terminals and control: L1, L2, L3, n Power consumption, not more than: 2 VA. The upper threshold Umax: 242 - 288 Century The lower threshold Umin: 173 - 219 C. Hysteresis: 5%. The time delay t (custom): 0.5 to 10 C. Output: The number and kind of output contacts: 1 changeover. Rated current contacts (AU-1): 8 A. Lockable power: 2000 VA (AC-1) / 240 watts (DC). Lockable voltage: 250V (AC-1) / 24 V (DC). Status indication: - green led - presence of the output signal; - red led - alarm voltage. Mechanical durability: 1×107 cycles. Switching durability: 1×105 cycles. Working temperature range: -20...+55 °C. Mounting on DIN rail EN 60715. Degree of protection housing: IP 40. Wire cross-section 2.5 mm2. Dimensions (weight): h,h mm (69 grams). Details see: http://relsis.ua/relsis/tree/Products/rele_napryazheniya/tehnicheskoe_opisanie_el-22n.htm Relay maximum voltage IO-4 Relay maximum voltage operational power to the IO-4 designed for electrical circuits switching devices protection and automation of power systems when reaching the input voltage of a certain pre-set level. Relay refer to static relays AC, frequency 50 Hz, with a discrete set setpoint voltage actuation or release and dial with numeric markers. Relays are manufactured in performances U3 and T3. Operating temperature range from minus 40 to plus 55°C. Details see: http://relsis.ua/relsis/tree/Products/rele_napryazheniya/tehnicheskoe_opisanie_nl-4.htm Other devices series IO, see: http://relsis.ua/relsis/tree/Products.htm