Regulators RS modifications are divided into the following:
RS 29.0.11 the Main entrances to five unified signals (three signals of 0-5 mA) resistive or inductive. The sensor positioner rheostat or inductive.
RS 29.0.12 the Main entrances to five unified signals (three signals of 0-5 mA) resistive or inductive. The sensor positioner rheostat or inductive.Arrow indication
RS 29.1.11 the Main entrances to three signals ±10mgn differential transformer sensors and up to two unified. The sensor positioner rheostat or inductive.
RS 29.1.12 Basic inputs — up to three alarms ±10mgn differential transformer sensors and up to two unified. The sensor positioner rheostat or inductive. Arrow indication
RS 29.0.42 Basic inputs — up to four unified signals. The sensor positioner rheostat.Additional features — analog-to-relay and dynamic change Arrow indication
RS 29.0.43 Basic inputs — up to four unified signals. The sensor positioner rheostat. Additional features — analog-to-relay and convert the Digital dynamic display
RS 29.1.42 the Main entrances to three signals ±10mgn differential transformer sensors and up to two unified. The sensor positioner rheostat. Additional features — analog-to-relay and dynamic change Arrow indication
RS 29.1.43 the Main entrances to three signals ±10mgn differential transformer sensors and up to two unified. The sensor positioner rheostat. Additional features — analog-to-relay and convert the Digital dynamic display
RS 29.2.22 the Main entrances to three resistance thermometers calibrations 50M, 100M, 23 and up to two uniform signals. The sensor positioner rheostat. Arrow indication
RS 29.2.23 the Main entrances to three resistance thermometers calibrations 50M, 100M, 23 and up to two uniform signals. The sensor positioner rheostat.Digital readout
RS 29.2.32 the Main entrances to three resistance thermometers calibrations 50M, 100M, 23 and up to two uniform signals. The sensor positioner rheostat. Additional features — analog-to-relay and nonlinear transformations (e.g., for the formation of the heating schedule for heating systems)analog display
RS 29.2.33 Bases. inputs — up to three RTD calibrations 50M, 100M, 23 and up to two uniform signals. The sensor positioner rheostat. Additional features — analog-to-relay and nonlinear transformations. Digital readout
RS 29.3.42 Bases. inputs from thermocouple calibrations HC, HA, PP, PR, BP with compensation of cold junctions, and two standard signal. The sensor positioner rheostat. Additional features — analog-to-relay and dynamic change Arrow indication
RS 29.3.43 Bases. inputs from thermocouple calibrations HC, HA, PP, PR, BP with compensation of cold junctions, and two standard signal. The sensor positioner rheostat. Additional features — analog-to-relay and convert the Digital dynamic display