The display ДМ3583
Price: | 3 700 UAH |
Seller: | Pokosenko Konstantin |
Phones: | +380501953117 Show phone |
Address: | Ukraine |
The display-Converter DM-3583М is designed to convert the pressure difference into the output unified signal of mutual inductance with linear dependence.
Area of application pressure switches-transducers DM-3583М:
Converters are used in systems of control, regulation and control of technological processes when measuring: - flow of liquid, gas or steam by difference in their pressures in the narrowing device; - the difference of vacuum or excess pressure; - fluid level in the hydrostatic pressure of the column under atmospheric, overpressure or vacuum pressures.
The transmitter DMT-3583М12 consists of a transducer DM-3583М and microprocessor unit БМ2.
Technical characteristics of the devices DM-3583М
The name of the parameter
Parameter values
DM-3583М
DMT-3583М-
DMT-3583М2
DMT-3583М EX
DMT-3583МЗ
DMT-3583М11
DMT-3583М12
The upper nominal measurement range, kPa
1,6; 2,5; 4,0; 6,3; 10; 16; 25; 40; 63; 100; 160; 250; 400; 630
The maximum allowable working overweight or obesit. pressure, MPa
16; 25
Output signals, mH, mA
0-10
0-5 ; 0-20 ; 4-20
5-0; 20-0; 20-4
0-5; 4-20
The limit of permissible reduced basic error of conversion, %
±1,0 ±1,5
±1,0
±0,6
The limit of permissible reduced basic error of indication value of the pressure difference, %
±0.6
The limit of admissible reduced-term basic error of readings of the consumption values, %
±0. b
The limit of permissible reduced basic error of integration, %
±0.6
Food:
current, a
voltage, V
frequency, Hz
0,125
50
220
50
36
50
220
50
Power consumption, VA
1.5
10(*)
10
10
10(*)
15
15
Operating temperature:°C
-30...+ 50
(DM-3583М, DM-3583М2, DM-3583М-Ex)
+5...+50
(BPL, BPL-1K-Ex БМ1, БМ2)
Relative humidity, %
95, for DM-3583М, DM-3583М2, DM-3583М Ex
80, to BPL, BPL-1K-Ex БМ1, БМ2
Overall dimensions, mm
180 x 192 x 302(DM-3583М)
180х261х300 (DM-3583М-Ex, DM-3583М2)
80 x 160 x 348 (BPL, BPL-1K-Ex БМ1, БМ2)
Weight, kg
12
15(*)
15,5
15
15(*)
15
15,2
The pressure switches of the type DM-3583 is designed to convert the pressure difference (in the system) in the inductive signal is output linearly. DM-3583 use in a production environment (factories, industrial sites) for the measurement of these indicators the working fluid as: pressure, differential pressure, flow and level of liquid or gas. These devices can fully function in a wide temperature range from -30°C to + 50°C.
A differential pressure gage with maximum values of 1.6 and 2.5 kPa is only for converting the output signal parameters of the gas, because it shifts a "zero" because of the difference of the liquid column between the membrane boxes. The primary winding of the Converter transformer of DM-3583М receives from the secondary device, the alternating current (I = 0.125 A) with a frequency (? = 50 Hz)