Complete transformer substation Bctu, 2 Bctu capacity up to 1000 kVA
Price: | negotiated |
Company: | Elektromarket |
Seller: | Elektromarket |
Phones: | 4922 305368;8-903-6471471 Show phone |
Address: | Russian Federation, Moscow |
Complete transformer substation type Bctu , Bctu capacity up to 1000 kVA is designed to receive and power distribution three-phase alternating current with frequency of 50 Hz at voltage up to 10 kV and conversion into electricity 0.4 kV and power supply various consumers in regions with a temperate climate from -45 °C to +40 °C. Bctu is one (two) transformer substation outer installation. All the hardware (excluding power transformers) meets the requirements of GOST 14695-80, GOST 14693-90 and THE 3412-025-03989649-2003. Climatic version and location category N1 in GOST 15150-69,15543.1-89.
Case 2 Bctu depending on performance can have 3-4 separate premises that provide installation power transformers and switching high voltage and low voltage equipment in separate rooms. Install all high-voltage and low-voltage equipment in different rooms, in articles 2 Bctu allows to perform switching operations in full control of all equipment, that gives the possibility to exclude some of the equipment from the electricity supply circuits.Design Bctu has the required natural ventilation, providing cooling the power transformer during operation. The substation is provided based active electric energy. High-voltage switching equipment in the composition Bctu made on the basis of new cameras CSR N with interrupter switches type WNPR. Low-voltage switching equipment presents new developments SHUR-6(10), low voltage switchgear-6(8), RSD, PBP. The number of outgoing lines and their currents can be changed upon customer request. SHUR-6(10) is made on the basis safety straps firm "Apator". This device also includes load switch type'ISERE, the panel metering and the cell's own needs.Low voltage switchgear-6(8) different from the wardrobe accounting and distribution, installation on the outgoing lines power circuit breakers.PBP (manual switches) performed on the base of the switch'ISÈRE has an internal busbars, which allows easy attach it to the products SHUR, low voltage switchgear, SN. According to the customer completeness products can be changed.Overall dimensions (excluding decorative roof):
Width, mm - 5700
Depth, mm - 5510
The height of the "0" point, mm - 2850
The height of the base block, mm - 1600
Estimated weight, t - 30,5
(495) 720-70-42; 903-720-70-42 ; 8-903-6471471 http://www.electromarcet.EN