The stabilizer phase cftcs eliminates the misalignment of the phases,the generation phase zero.
Price: | 12 400 UAH |
Seller: | Voronin Oleg |
Phones: | 067 445 17 86 Show phone |
Address: | Ukraine, Khmel'nyts'ka Oblast', Netishyn |
The usage of our devices will ensure the quality of electricity in accordance with European standard EN 50160-94 and Interstate standard GOST 13109-97
Properties:
1. The equalization of the distortions of the phase voltages.
2. The suppression of higher harmonics that can adversely affect operation of electrical equipment.
3. The elimination of "dips" and surges in the electrical network.
4. Suppression intentional and unintentional pulses in the electrical network, including lightning and switching.
5. Automatic generation of one of the phases, or zero, in the event of breakage,
A device that saves electricity.
It is known that the connection is asymmetric (single-phase motors, welding machines, industrial and household appliances, production lines) and nonlinear (computers, air conditioners, TVs) loads in the electric supply network and the transformer (10kV/380V), increase of losses of active energy, especially in rural areas. The consequence of this is additional heating of the wires and transformer, insulation aging which is 1.5-2 times faster.
Connect SF to the network virtually eliminates currents and the higher harmonics in the phase wires, including zero, which reduces the energy losses in low voltage network and the supply transformer (reduced heating of the magnetic core and transformer tank), ensures energy savings of up to 8% and higher, depending on the nature of the load.
Converting two phases into three.
Burnout of one of the fuse leads to the disappearance of voltage in one of phases of the network or in the neutral wire. Connect SF provides automatic recovery voltage in that phase, where they fuse as well as generation zero. In this case, the consumer of electricity and the network personnel may not even notice that the network phase has disappeared or lost zero.
Reduces transient voltages and voltage dips.
When enabled, industrial and household appliances can change the brightness of the incandescent lamps, can be heard crackling in the operation of the radio equipment, operation of protection systems, etc. After joining SF such phenomena disappear.