Gauge signal showing condensation thermometer TCH-SG-M2 is used to measure the thermal parameters and control of external electrical circuits from signaling devices devices.
Thermometers TCH-SG-M2 divided into remote and local (with rigid connection).
Connecting the bulb with housing for local thermometers is available in two versions:
- with the radial location of the bulb;
- with the axial location of the bulb.
- electric heating boilers, water heaters, thermostats, oil-immersed transformers, saunas, temperature control modes heating elements for domestic and industrial installations (injection molding machines, presses for the manufacture of rubber and plastic, etc.).
The connecting capillary remote thermometers TCH-SG-M2 protected against external mechanical influences copper braid, or polyethylene, or spring, or PVC sheath.
Specifications condensation signaling manometric thermometer TCH-SG-M2
Characteristics values of the measurement range, °C -25 ° C to +75; from 0 to +120; from +100 to +200; from +200 to +300 the Length of the connecting capillary remote thermometer TCH-SG-M2, m 0,6; 1; 1,6; 2,5; 4; 6; 10; 12; 16; 25 Length of immersing the bulb, mm 160, 200, 250, 315, 400, 500, 630, 800, 1000 the Diameter of the bulb, 12 mm, 14, 16 accuracy Class temperature TCH-SG-M2 1,5; 2,5 environmental Pressure, MPa, not more than 1.6 Voltage signaling devices, not more than 220 (50 Hz) Breaking capacity contact signaling devices,·And 50 Weight TCPs-M2, kg: - remote (with capillary 25 m) 4,5 - local 2,5 Average service life, years, not less than 10, the Material of the bulb drugs 59-1; 12X18H10T view of a protective sheath capillary for remote thermometers: - copper A - PE B - polyvinyl chloride G Filler tap system-SG-M2 depending on the limit of the measurement methyl chloride technical GOST 12794-80 acetone GOST 2758-84 toluene GOST 5789-78 halon GOST 8502-93
Notes:
- tolerance length immersing the bulb up to 250 mm (± 3 %);
- tolerance of the length of the connecting capillary ± 10 %;
- working limit of the measurement TCH-SG-M2 must be equal to the last 2/3 of the measuring range.
Thermometer gauge signal TCH-SG-M2 manufactured by THE 25-02.091870-81.
Order form TCH-SG-M2 Symbol TCH-SG-M2 when orderingThe example gauge signaling thermometer for
the operating conditions of the execution UHL2 measurement range (0 to 120) °C,
accuracy class 1.5, the length of the connecting capillary 10 m length
dip the bulb 400 mm and a polyethylene sheath during recording
or order:
TCH-SG-M2-UHL2(0-120)-1,5-10-400-B TO-02091870-81.
Same for local thermometers:
TCH-SG-M2-UHL2 (0-120)-1,5 TO-02091870-81.
The same for the execution of T2 copper jacket:
TCH-SG-M2-T2(0-120)-1,5-10-400-AND TO-02091870-81.
Local signaling thermometers are manufactured without electric compounds (temple, socket). On special request of customer thermometers can be made with connectors.
The electrical circuit of the thermometer TCH-160-CR-M21 is a circuit diagram;
2 diagram of external connections;
To contact;
N - normal;
General. .