Thermometer gauge, condensation,

showing signaling TCH-SG-M3

TCH-SG-M3 - a new generation of thermometers gauge signal TCH-SG, replacing one of the the most reliable signaling thermometers TCH-SG-M2.

Thanks the use of new technologies of production of parts, we were able to make thermometer easier, while increasing reliability, reducing the time manufacture and cost of the device.

 

TCH-SG-M3:

• High reliability due to the absence in the design tribco-sectoral mechanism.

• Signalling device on the dip switches.

• Breaking capacity of contacts A.

• Wall and panel performance

• Weight measuring part 1,0 kg

• Manufacturer's warranty-36 months.

 

Designed for continuous measurements of water temperature, oil and other liquids, non-corrosive to the materials of the bulb (brass LS-1 or steel 12X18H10T), and management of external electrical heating circuits elements or facilities.

 

Specifications

 

The limits of measurement, °C -25...+75 0...120 100...200 200...300 the Aggregate of the thermal system Halocarbon 22 methylene chloride acetone toluene accuracy Class 1,5; 2,5 Length of the connecting capillary, m 0,6; 1,0; 1,6; 2,5; 4,0; 6,0; 10; 12; 16; 25 the immersion Depth of the bulb, mm 160; 200; 250; 315; 400; 500; 630; 800; 1000 the Diameter of the bulb, mm 12; 14; 16 16 Material the bulb Brass LS-59, gr.the stainless steel.steel containment capillary And copper, B - polyethylene And copper Breaking capacity of contacts signaling devices, VA 50 climatic version according to GOST 15150 UHL2, T2, TV3 Voltage external switching circuits AC, 220V/50Hz for performances UHL2, T2 250V/60Hz for execution TV3 Group vibration L3 according to GOST 12997-84 Calibration interval 1 year Warranty period 36 months lifetime, not less than 10 years

 

 

In terms of resistance to mechanical stress are vibration-proof.
Resistance to climatic influences correspond to version NF category 2 according to GOST 15150, but at a temperature of from -50 to +60 ° C, T 2 and TV category 3 according to GOST 15150, but for works in temperatures from minus 10 to plus 55 °C.

 

The calibration interval is 1 year.

 

Produced by SNIC.405 153.008

 

Pressure the medium 1,6 MPa, at the request of the customer bulbs made for nominal pressure of 6.3 MPa; with a protective sleeve to 24.5 MPa (protective sleeve in the not supplied, manufactured on special. order).
The average life of not less than 10 years.

Note. For a thermometer with a measuring range of 200-300°C bulbs made of stainless steel. The bulbs with a diameter of 12 and 14 mm also made from stainless steel.

 

Panel performance

 

 

 

The wall version