Tube AY,tube LOI,tube LOI
Price: | negotiated |
Seller: | Byihovets Ol'ga Vladimirovna |
Phones: | 0667371320 Show phone |
Address: | Ukraine, Chernihivs'ka Oblast', Chernihiv |
The outputs of the electrodes: 1, 14 - heater; 2 - cathode, 3 - modulator 4 is the first anode (focusing), 5 - third anode 7 - second anode; 9 - shielding plate; 10 - mesh; X1, x2 - temporary deflecting plate; Y1, Y2 signal deflecting plates; And a fourth anode; 6, 8, 11, 12, 13 - not connected.
The main parameters of the device odnovremenno tube LO
when UH = 6,3; Uа1 = 250...450 V, U*a2 = ±50V; U**a3 = ±50V; U**a4 = ±8kV discharge; U*Zap = -(30...75);
U** ECR.the formation .= ±50V; U**c = ±50V; IR =-2kV
where * is the voltage measured relative to the cathode,
** - the voltage measured relative to the average potential of the signal plate.
Miniature odnovremenno tube LOI (70g.,G.) with a screen of rectangular shape with a convex surface. Designed for visual observation of electric processes in electronic devices.
Light color screen odnovremenno tube LOI green. The size of the working part of the screen Hm. The width of the focused line in the center of the screen is not more than 0.3 mm, the Outputs of the electrodes: 1, 14 - heater; 2-cathode, 3 - modulator 4 is the first anode; 6, 12-modulator; 7 - temporary deflecting plate X1, 8 - temporary deflecting plate x2, 9 - second anode 10 signal deflecting plate U1; 11 - signal deflecting plate U2, 5, 13 is not connected.
Design - glass benzocaine. Weight 0,2 kg
The main parameters of the device single-beam Tube LOI
when UN = 6,3; Ua1 = 45...135B; Uа2 = 1,2 kV; Uзап = -(30...90).
Dopaminea tube LOI separate EOS with Blankie plates and anode astigmatism correction, with one degree plaplacian, with the screen round shape with a flat surface. Dopamine tube LOI designed for visual observation of two independent electrical processes simultaneously in electronic devices. Color screen - yellow-green. The size of the working part of the screen Hm.
The outputs of the electrodes: 1 - fourth anode (a, b), 2 - modulator (a), 3 - the first anode (focusing electrode) (a), 4, 5 - heater (a), 6 (third anode (a), 7 - cathode (a), 8 - blancou plate, 9 - second anode; 10 - cathode (C), 11 - third anode (in); 12, 13 - heater (in), 14 - first anode (focusing electrode) (in ); 15 - modulator (in); AZ - outlet - balloon-fifth anode; X1 (), x2 (and) - side outputs on the cylinder - temporary decline; Y1 (a) Y2 (a) - side outputs on cylinder signal deflecting plates; X 1 (in), X 2 (in) - side outputs on the cylinder - time deflecting plate; Y1 (), Y2 (b) - side outputs on cylinder signal deflecting plates of the plate. Letters (a) and (b) shows the two different electrodes preneoplastic systems. Design - glass benzocaine with additional outputs to the ball bosom. Weight 0.8 kg
The main parameters of the device dopaminea tube LOI
when UN = 6,3; Ual = 200...400; Ua2 = 900V; U3an = -(10...30)V; U3an.form.PL≤ 30V;
LI g.(1pc.)
LOI 70g.(1pc),g.(1pc)
Dopaminea tube NOW (74g.) separate EOS, with one degree plaplacian, with the screen of rectangular form with a flat surface. Dopaminea tube MOV is designed for visual observation of two independent or paulproteus electric processes simultaneously in electronic devices. Color screen - blue; the color of the afterglow yellow. The size of the working part of the screen not less than Hm. The width of the focused line in the center of the screen is not more than 0.8 mm; at a distance of 40mm from the centre of the screen not exceeding 1 mm.
The outputs of the electrodes: 1, 20 - heater (s), 2 - modulator (a); 4 - the second anode (a); 5 - time deflecting plate X1 (a), 6 - second anode (a, b); 7 - time deflecting plate X1 (in); 8 - the first anode (in); 9 - cathode (C); 10, 11 - heater (in); 12 - modulator (in); 14 - the second anode (in); 15 - temporary deflecting plate 2 (C), 17 - temporary deflecting plate x2 (a); 18 - the first anode (a); 19 - cathode (a); signal deflecting plates Y1 (a) Y2 (a) Y1 (b) Y2 (b) - side outputs on the neck of the container; A3 is the third anode - side outlet on the cylinder; 3, 13, 16 is not connected. Letters (a), (b) the designated electrodes of two different promentory systems. Design - glass with base. Weight 1,9 kg
The main parameters of the devices dopamine tube MOV
when UH = 6,3; Uа1 = 350...650V; Ua2 = 2Q; Ua3 = 3Q; Uзап = -(1 40...