Multimeter-Fluke 1587 megger - digital combined apparatus, which is an insulation resistance meter and multimeter full-featured, integrated in a compact portable tool. Like other instruments manufactured by Fluke, model Fluke-1587 durable, reliable, simple and easy to use. The Fluke 1587 combines in the same housing digital meter insulation resistance with a test current of 1 mA and a full-featured digital multimeter. The device is intended for predictive maintenance of electric motors, electric motors, generators, cables and switching devices. Mode megger Fluke 1587 provides insulation resistance measurement up to 2 Gω, with five values of the test voltage: 50, 100, 250, 500 and 1000 V
In the mode of a multimeter the Fluke 1587 provides a voltage measure AC and DC currents up to 1000 V, current up to 400mA resistance up to 50 Mω, and also allows verification of the integrity of the electrical circuit. In addition, the Fluke 1587 provides a capacitance measurement to 9, 999 microfarads, frequency to 100 kHz, temperature range -40...+537 °C (thermocouple K type) and testing of diodes; further include a low pass filter. The model has a wide LCD display mode backlight to work in poorly lit environments. Fluke 1587 withstands power surges up to 8 kV, the maximum voltage in a circuit when the insulation resistance measurement is 30 V. the Fluke 1587. General settings
- Insulation resistance up to 2 Mω
- Test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
Post. / AC voltage 0-1000 V (resolution of 0, 1, mV) - Post. / AC 0-400 mA (resolution of 0, 01 mA) - Resistance 0-50 Mω (resolution of 0, 1, Ω) - Error of 0, 09%
- Measurement of frequency, capacitance, temperature
- Diode test
- Battery
- Shockproof, dustproof and waterproof
- Weight: 0, 6 kg
Technical data the Fluke 1587: Parameters Values
Voltage DC Maximum voltage: 1000 V
Precision: ±(0, 09%+2) Maximum resolution: 0, 001 To
Voltage AC Maximum voltage: 1000 V
Accuracy: ±(2%+3) bandwidth AC: 5 kHz*
(*with low pass filter, 3 dB at 800 Hz) Maximum resolution: 0, 1 mV
DC Maximum current: 400 mA
The measurement error of current strength: ±(0, 2%+2) Maximum resolution: 0, 01мА
AC Maximum current: 400 mA
The measurement error of current strength: ±(1, 5%+2) *
(* bandwidth 1 kHz) Maximum resolution: 0, 01мА
Resistance Maximum resistance: 50 Mω
Precision: ±(0, 9%+2) Maximum resolution: 0, 1 Ohm
Capacitance Maximum capacitance: 9, 999 microfarads
Precision: ±(1, 2%+2) Maximum resolution: 1 nF
Frequency Maximum frequency: 100 kHz
Precision: ±(0, 1%+1) Maximum resolution: 0, 01 Hz
Temperature measurement from -40 to 0 °C to 537 °C
-40, 0 °F to 998 °F
eliminating the dipstick
Diode test Range: 6 To
Resolution: 1 mV
Accuracy: ±(2 % + 1) insulation check of the
Minimum test current at 1 kOhm/V 1 mA
Test voltage 50, 100, 250, 500, 1000
Maximum resistance with test voltage 50, 100, 250, 500, 1000 In 2 D
The maximum resolution at test voltage 50 V: 0, 01 IOM
100: 0, 01 IOM
250: 0, 1 MOhm
500: 0, 1 MOhm
1000: 0, 1 MOhm
Error in test voltage 50 V: ±(3 % + 5) 100 V: ±(3 % + 5) 250 V: ±(1, 5 % + 5) 500 In: ±(1, 5 % + 5) 1000 In: ±(1, 5 % + 5) to 600 Mω, ±(10 % + 3) above 600 Mω
Requirements to the environment
Operating temperature -20 °C to +55 °C
Storage temperature -40°C to +60°C
Humidity (without condensation) 0% - 95% (10 °C – 30 °C) 0% - 75% (30 °C – 40 °C) 0% - 40% (40 °C – 55 °C) operating altitude above sea level 2000 m
Electric safety standard
Category high voltage Conforms to standards ANSI/ISA 82. 02. 01 (61010-1) 2004, CAN/CSA-C22. 2 No. 61010-1-04, and IEC/EN 61010-1 2nd and