Bizator  /  Adverts  /  equipment and materials  /  industrial equipment  /  compressors, pumps, compressor equipment

Sell chemical pumps

Offer type: salePublished: 27.02.2015
Price:negotiated
Company:TOV 'Elektroprom +'
Seller:Natal'ya
Phones:
Show phone
Write a message
Address:Ukraine, Kyiv
Pumps chemical type X, pumps, CW pumps CHILLER - centrifugal, horizontal, cantilevered, single stage designed for pumping chemically active and neutral liquids to max density 1850 kg/m3, containing solids in an amount of not more than 0.1% by volume with a particle size of not more than 0.2 mm, the kinematic viscosity of up to 3x10-6 m2/s Pump the Pumped medium Material performance Type Version description the Temperature of the liquid end seal Type Pump HEH WITH explosion-proof motor Flammable and explosive liquid BOD, 5, 55 Pump X And Chemically active and neutral liquids with density not exceeding 1850 kg/m3, for which the penetration rate of corrosion in the material flow path is less than 0.1 mm/year from 313 To 393 K (from -40°C to +120°C) Steel hromonikelemolibdenovyh HTL DM, 5, 55 From 313 To 393 K (from -40°C to +120°C) chromium-Nickel Steel 12H18N9TL DM, 5, 55 E from 313 To 393 K (from -40°C to +120°C) Steel Nickel ST DM, 5, 55 And from 313 To 393 K (from -40°C to +120°C) Carbon steel 25L DM, 5, 55 The pump On the Content of solid inclusions of a size not exceeding 0,2 mm - not more than 0.2% by volume. The kinematic viscosity of the fluid up to 30 cm2/s from 273 K To 363 K (0°C to +90°C) Chromium cast iron BOD, 5, 55 M from 313 To 393 K (from -40°C to +120°C) Steel chroniclingamerica 16H18N12S4TYUL DM, 5, 55 L from 273 K To 343 K (0°C to +70°C) Silicon cast iron BOD, 5, 55 T from 273 K To 343 K (0°C to +70°C) Titanium alloy DM, 5, 55 Pump HO from 273 To 523 K (0°C to +250°C) BOD, 5, 55 Pump CHILLER from 313 To 393 K (from -40°C to +120°C) chromium-Nickel Steel HAM Pump shaft seal: 5 (55) - end single (double); (DM) - packing single (double). Example chemical pumps Pump X 80-50-200A-To-SD X - unit for chemical production. 80 - diameter of pipe, mm 50 - diameter, mm. 200 - impeller diameter, mm and (b) turning the impeller. To - execution. DM - lip shaft seal (double). Pump CHILLER 2/25-TO-5 HMM - pump for chemical production. M - horizontal monoblock. 2 - flow, m3/h 25 head, m, To - execution. 5 - sealing shaft end (single). Main technical characteristics and dimensions of pumps chemical X, HO, HM Model pump pump Parameters motor Parameters Flow, m3/h Head, m rotation Frequency, Rev/min engine Power, kW Pump X 50-32-125 12,5 20 2900 4 Pump X 50-32-125 10,5 14 2900 4 Pump HO 50-32-250 12,5 80 2900 30 Pump HO 50-32-250a 11,5 2900 67 22 Pump X 65-50-125 25 20 2900 5,5 Pump X 65-50-125 23 17 2900 5,5 Pump HO 80-50-250 50 80 55 2900 Pump HO 80-50-250a 45 67 2900 45 Pump HO 100-80-160 100 32 30 2900 Pump HO 100-80-160A 90 26 30 2900 Pump HO 100-65-200 100 50 55 2900 Pump HO 100-65-200A 90 40 30 2900 Pump HO 100-65-250 100 80 90 2900 Pump HO 100-65-250a 90 67 75 2900 Pump X 100-65-315 100 125 200 2900 Pump X 100-65-a 90 105 160 2900 Pump X 65-50-160 25 32 11 2900 Pump X 65-50-160A 22,5 26 2900 7,5 Pump HO 80-50-200 50 50 30 2900 Pump HO 80-50-200A 45 40 30 2900 Pump X 80-65-160 50 32 11 2900 Pump X 80-65-160A 22,5 26 2900 7,5 Pump HO 150-125-315 200 32 1450 75 Pump HO 150-125-a 180 26 1450 55 Pump X 150-125-400 200 50 110 1450 Pump X 150-125-400A 180 40 90 1450 Pump HO 200-150-315 315 32 1450 75 Pump HO 200-150-a 290 26 1450 55 Pump X 200-150-500 315 80 1450 200 Pump CHILLER 2/25-2 25 1,5 2900 Pump CHILLER 32-20-C 3,15 25 2900 0,7 Pump type AH - centrifugal, horizontal, cantilevered, single stage. Designed for pumping chemically active and neutral liquids to max density 1850 kg/m3, viscosity up to h-6 m2/s, containing solids up to 1 mm, the volume concentration not exceeding 1,5%. Fluid temperature from 233 to 393 K (-40 to +120°C). Example chemical pumps Pump AH 100-65-400-TO-DM-U2 AH - pump for liquids with abrasive particles and chemicals. 100 - diameter of pipe, mm 65 - diameter, mm. 400 - impeller diameter, mm To the designation of the material parts of the flow. DM - lip shaft seal (double). U - climatic. 2 - category of location of the unit during operation. Main technical characteristics and dimensions of pumps AH Pump model Flow, m3/h Head, m speed, s-1 (about./minutes) Tolerance. cavitation. stock, m motor Power, kW Weight of pump (kg) Density, t/m3 1.3 to 1.85 OH 3-15 K,E,AND 3 15 48 (2900) 5 3 - 29 OH 40-25-160 K,E,AND 6,3 32 48 (2900) 3 4 5,5 46 OH 50-32-160 K,E,AND 12,5 32 48 (2900) 3,5 5,5 7,5 49 OH 50-32-200 K,E,AND 12,5 50 48 (2900) 3,5 15 18,5 60 OH 65-40-200 K,E,AND 25 50 48 (2900) 4 15 22 57 OH 100-65-315 K,E,AND 50 32 24 (1450) 3 15 22 125 OH 100-65-a K,E,And 44,5 25 24 (1450) 3 11 15 125 OH 100-65-b K,E,And 39 20 24 (1450) 3 11 11 125 OH 100-65-400 K,E,AND 50 50 24 (1450) 3 30 37 186 OH 100-65-400A K,E,And 44 39 24 (1450) 3 22 30 186 OH 100-65-b K,E,And 40 33 24 (1450) 3 18,5 22 186 OH 125-80-250 K,E,AND 80 20 24 (1450) 4 15 18,5 105 OH 125-100-315 K,E,AND 125 32 24 (1450) 4 37 45 160 OH 125-100-a K,E,And 112 26 24 (1450) 4 30 37 160 OH 125-100-b K,E,And 102 21,5 24 (1450) 4 22 30 160 OH 125-100-400 K,E,AND 125 50 24 (1450) 4,5 55 75 200 OH 125-100-400A K,E,And 112 41 24 (1450) 4,5 45 55 200 OH 125-100-b K,E,And 105 35 24 (1450) 4,5 45 45 200 OH 150-125-315 K,E,AND 200 32 24 (1450) 6 55 75 185 OH 150-125-a K,E,And 180 27 24 (1450) 6 45 55 185 OH 150-125-b K,E,And 165 21 24 (1450) 6 30 37 185 OH 15-50 K,E,AND 315 50 24 (1450) 6 75 90 490