Power cables with copper or aluminium conductors, XLPE insulation, Pwga, APWG,Pluging(A), Apwhen(A),Pluging(A)-PI, Apwhen(A)-PI,Pluging(A)-LS
Price: | negotiated |
Company: | OOO 'RTK 'Novyie Tehnologii' |
Seller: | Anton Berkut |
Phones: | +7(342)202-60-77 Show phone |
Address: | Russian Federation, Perm Krai, Perm |
Pwga, APWG,Pluging(A), Apwhen(A),Pluging(A)-PI, Apwhen(A)-PI,Pluging(A)-LS, Apwhen(A)-LS
Pwga, APWG
Power cables with copper or aluminium conductors with XLPE insulation and sheath of PVC, shielded
Pluging(A), Apwhen(A)
Power cables with copper or aluminium conductors, XLPE insulation, sheath made of PVC with low Flammability, shielded
Pluging(A)-PI, Apwhen(A)-PI
Power cables with copper or aluminium conductors, XLPE insulation, sheath made of PVC with low Flammability cold-resistant, shielded
Pluging(A)-LS, Apwhen(A)-LS
Power cables with copper or aluminium conductors with XLPE insulation and sheath of PVC low fire danger, shielded
APPLICATION
For transmission and distribution of electricity in fixed installations with nominal alternating voltage of 0.66 and 1 kV nominal frequency of 50 Hz.
The cables are designed for the needs of national economy and are used in industrial and energy facilities. The cables in the performance of ng(A)-LS ' may be operated in systems of nuclear power plants classes 2, 3 and 4 on the classifier OPB 88/97 (PNAE G-01-011).
Cables with XLPE insulation and outer sheath made of PVC are designed for single laying in cable installations and industrial premises. Group laying data cables is only permitted in outdoor installations and industrial premises, where the only possible periodic presence of staff. It is necessary to apply the passive fire protection.
Cables with XLPE insulation outer sheath of PVC low Flammability performed by ng(A) are intended for laying in cable structures and external (open) electrical installations, namely, cable racks and galleries.
Cables with XLPE insulation and outer sheath of PVC low fire danger in the performance of ng(A)-LS" designed for group laying in cable structures and premises internal (closed) electrical installations, including nuclear energy, as well as for use in residential and public buildings.
Cables with XLPE insulation and outer casing of cold-resistant PVC compound with low Flammability performed by ng(A)-PI" intended for group laying in cable structures and premises external (open) electrical installations, including those used in climates with low temperature to 60 OC.
OKP CODES
352100 cable with copper conductors for nominal voltage 0,66 kV
353300 cable with copper conductors for nominal voltage 1 kV
352200 cable aluminium conductors for nominal voltage 0,66 kV
353700 cable aluminium conductors for nominal voltage 1 kV
DESIGN
1. Conductor - copper or aluminum, solid or stranded, circular or sector-shaped, 1 or 2 class according to GOST 22483.
2. Insulation - XLPE Insulated conductors of multi-conductor cables have distinctive coloring. Isolation zero-lived (N) is blue. Isolation lived grounding (PE) is a two-color (green - yellow) color. Nominal thickness of insulation color insulation stranded cables are provided in Appendix p.
3. Twisting - isolated veins of two-, three-, four - and patriliny cables twisted; two - three - and patriliny cables have conductors of the same cross section; a four-wire cables have all wires of the same cross-section or one core of a smaller cross-section (vein of earth (PE) or zero(N)). Nominal cross-section of the zero conductors (of smaller size) and lived grounding correspond to those specified in the Annex on page
4. The inner shell for multiconductor cables are trademarks of APWG, Pwga of PVC in cables brands Apwhen(A), Pluging(A) of PVC low Flammability, cables brands Apwhen(A)-PI, Pluging(A)-PI of cold-resistant PVC compound with low Flammability, cables brands Apwhen(A)-LS, Pluging(A)-LS of PVC low fire danger.
The inner shell fills the interstices between the insulated conductors of the multiwire cable, giving the cable a form similar to the round. The nominal thickness of the inner shell are shown in the Annex on page
The separation layer for single-core cables winding of insulated conductors polymeric tapes.
5. The screen - winding of copper tape with a minimum thickness of 0.06 mm overlap. The cross-section of the copper screen are shown in the Annex on page
6. The outer casing - in cables grades APWG, Pwga of PVC in cables brands Apwhen(A), Pluging(A) of PVC low Flammability, cables brands Apwhen(A)-PI, Pluging(A)-PI of cold-resistant PVC compound with low Flammability, cables brands Apwhen(A)-LS, Pluging(A)-LS of PVC low fire danger. The nominal thickness of the membranes are listed in the Appendix on page
SPECIFICATIONS
Type of climatic version according to GOST 15150-69:
Cable brands of APWG, Pwga UHL, T., placement category 1 and 5
Cable brands Apwhen(A), Pluging(A) UHL, category 3 and 5
Cable brands Apwhen(A)-PI, Pluging(A)-PI category of service