Bizator  /  Adverts  /  equipment and materials  /  industrial equipment  /  electrical survey units

Sapphire-22-DI-2110,Sapphire 22 DI 2110,Sapphire

Offer type: salePublished: 01.03.2015
Price:negotiated
Seller:Sergej Paseka Dmitrievich
Phones:
Show phone
Write a message
Address:Ukraine

Gage pressure with outside measurements 0,16; 0,25; 0,4; 0,6; 1,0; 1,6 kPa and an accuracy class 0.5%; 0.25%; of 0,15%

Converters Sapphire-22-DI-2110 are portable and can be reconfigured at any of the measurement range for this model. Converters Sapphire-NS-DI-2110 digital signal processing, by order, may be adjusted to any non-standard limit of measurement in the range from 0.16 kPa up to 1.60 kPa.

On customer's request, the sensors can be supplied with a measuring range in pressure units kgf/m2 kgf/cm2, bar and mbar.

The execution of ex:

Ordinary;
"Ex" - "intrinsically safe electrical circuit" with ex approval "0ExiaIICT5 X".
"NR" - "pravonarushiteley sheath" with ex approval "1TxdsIIBT4/H2"
Maximum permissible error:

0,5 %;
0,25 %;
0,15 %.
Execution according to the materials of the parts of the transducers in contact with the measured medium:

Designation material design Material measuring membrane Flanges, nepela
01 Alloy 36NHTYU Carbon steel coated
02 Alloy 36NHTYU Steel 12X18H10T
05 Tape BMTC (WAC-6) Steel 12X18H10T
07 Tantalum Steel 12X18H10T
09 Titanium VT1-0 Titanium alloy
The working temperature of the measured environment from -30 to 120 °C with the direct connection of the Converter.

Climatic version:

NF3.1 for operation at ambient temperatures of -1.. 50°C;
U2 - for operation at ambient temperatures -40.. 80 °C, on the order of -50... 80°C;
T3 for operation at an ambient temperature of 1.. 80°C; on the order of -10 to 80°C.
The output signal of the sensors in the ordinary and explosion-proof execution("EXT"):

0-5 mA two-wire and four-wire communication line;
0-20 mA two-wire and four-wire communication line;
4-20 mA two-wire and four-wire communication line.
The output signal explosion-proof versions with explosion protection "intrinsically safe electrical circuit" - "Ex":

4-20 mA two-wire communication line.
Voltage converters with output signal 0-5 mA and 0-20mA - stabilized DC voltage from 24V to 36V.

Voltage converters with output signal 4-20mA - stabilized DC voltage from 15V to 36V.

Power converters Sapphire-22-DI-Ex-2110 in tribosystem the version with type of protection "intrinsically safe electrical circuit" is from an intrinsically safe power supply BPS-90, BPS-96 or other with type of protection "intrinsically safe electrical circuit" "ia" for explosive mixtures of group IIC" Ui-less than or equal to 24V.