Sapphire-22-DIVAS-2310,Sapphires,Sapphire 22 DIVAS 2310
Price: | negotiated |
Seller: | Sergej Paseka Dmitrievich |
Phones: | 0674731222 Show phone |
Address: | Ukraine |
Pressure sensors-rarefaction with outside measurements±0,08; ±0,125; ±0,2; ±0,3; ±0,5; ±0,8 kPa and an accuracy class 0.5%; 0.25%; of 0,15%.
Converters Sapphire-22-DIVAS-2310 are portable and can be reconfigured at any of the measurement range for this model. Converters Sapphire-NC-DIVAS-2310 digital signal processing, by order, may be adjusted to any non-standard limit of measurement range from ±0.08 kPa ±0,8 kPa.
On customer's request, the sensors can be supplied with a measuring range in pressure units kgf/m2 kgf/cm2, bar and mbar.
The execution of ex:
Ordinary;
"Ex" - "intrinsically safe electrical circuit" with ex approval "0ExiaIICT5 X".
"NR" - "pravonarushiteley sheath" with ex approval "1TxdsIIBT4/H2"
Maximum permissible error:
0,5 %;
0,25 %;
0,15 %.
Execution according to the materials of the parts of the transducers in contact with the measured medium:
Designation material design Material measuring membrane Flanges, nepela
01 Alloy 36NHTYU Carbon steel coated
02 Alloy 36NHTYU Steel 12X18H10T
05 Tape BMTC (WAC-6) Steel 12X18H10T
07 Tantalum Steel 12X18H10T
09 Titanium VT1-0 Titanium alloy
The working temperature of the measured environment from -30 to 120 °C with the direct connection of the Converter.
Climatic version:
NF3.1 for operation at ambient temperatures of -1.. 50°C;
U2 - for operation at ambient temperatures -40.. 80 °C, on the order of -50... 80°C;
T3 for operation at an ambient temperature of 1.. 80°C; on the order of -10 to 80°C.
The output signal of the sensors in the ordinary and explosion-proof execution("EXT"):
0-5 mA, 5-0 mA two-wire and four-wire communication line;
0-20 mA, 20-0 mA two-wire and four-wire communication line;
4-20 mA, 20-4 mA two-wire and four-wire communication line.
The output signal explosion-proof versions with explosion protection "intrinsically safe electrical circuit" - "Ex":
4-20 mA two-wire communication line.
Voltage converters with output signal 0-5 mA and 0-20mA - stabilized DC voltage from 24V to 36V.
Voltage converters with output signal 4-20mA - stabilized DC voltage from 15V to 36V.
Power converters Sapphire-22-DIVAS-Ex-2310 in tribosystem the version with type of protection "intrinsically safe electrical circuit" is from an intrinsically safe power supply BPS-90, BPS-96 or other with type of protection "intrinsically safe electrical circuit" "ia" for explosive mixtures of group IIC" Ui-less than or equal to 24V.
Labeling kit mounting parts when ordering:
K1/2 - Flange for connecting the measuring line pressure with the screw hole K1/2;
K1/4 - Flange for connecting the measuring line pressure with the screw hole K1/4;
M20 - Flange with fitting under the cap nut with thread M20/1,HD;
SK - Bracket and bracket for installing the device on the pipe 60mm;