Bizator  /  Adverts  /  equipment and materials  /  power engineering equipment  /  electric power stations equipment

The control unit of the resistance type BCS-2

Offer type: salePublished: 09.09.2016
Price:500 UAH
Seller:Aleksandr
Phones:
Show phone
Write a message
Address:Ukraine, Chernihivs'ka Oblast', Chernihiv

The description and use of the control unit the resistance of BKS-2:

The control unit of the resistance type BCS-2 is designed to control one (BKS-2.1) or two (BCS-2.2) levels of conductive liquid and dry environments (water, ore, rock, coal, etc.) with one or two electrode sensor level.

Unit BKS-2 is installed out of explosion hazard premises and external installations.

Level sensor BCS-2 meets the requirements of GOST 22782.5-78 and bears the marking "OExiaIICT6" complete with BKS-2I. The sensor is designed for installations in explosive zones of premises and external installations according to sec. 3 pack "regulations for electrical installation (RB-76 )" and other legislative documents regulating the installation of electrical equipment in hazardous areas.

Control unit BKS-2 can also operate on other commercially available contact sensors that meet the requirements above.

The block resistance of BKS-2 produced in UHL location category 3 according to GOST 15150-69, the conditions of operation of the following:

  • height above sea level up to 2000 m;
  • ambient temperature from minus 40 to plus 40 °C;
  • the vibration of fixing up to a frequency of 35 Hz and an acceleration of 0.5 g;
  • relative humidity up to 98% at 25 °C without moisture condensation;
  • the environment does not contain aggressive gases and vapors in
  • the concentration destroying metals and insulation;
  • working position and the vertical space.

Technical characteristics of the control unit the resistance of BKS-2:

  • Rated voltage, V: 220;
  • The allowable voltage deviation, %: -15; +10;
  • Frequency, Hz 50
  • The ranges of controlled resistance, com. not already within: 0..150; 0...6300;
  • Power consumption, VA, not more than 7;
  • Number of contacts unit pack:
- guard 1;
- switching 2;
  • Voltage switching contacts, V, not more than: 220, 380*;
  • Switching current. And, not more than 4;
  • The mean time to failure, h, not less than 15 000;
  • Service life, years: 6;
  • Weight, kg, not more:

unit BKS-2 1,4;
- remote sensor 0,6;

* with two switch contacts.

In stock 4 PCs