Bizator  /  Adverts  /  equipment and materials  /  industrial equipment  /  gas-meters, gas equipment

Woltex WE Counters turbine

Offer type: salePublished: 01.03.2015
Company:TOV 'Torgovo-promyishlennaya kompaniya 'Tehnoprom'
Seller:Sergej Aleksandrovich
Phones:
Show phone
Write a message
Address:Kyiv, Ukraine

1.1 Meters turbine Woltex WE... (hereinafter the counters), manufactured at the plant of IHOP Lapse (France), designed for measuring the volume of cold potable and technical water (temperatures up to 50 °C) or hot water (temperature up to 130 °C) municipal or main water supply, and also the industrial sector.

1.2 meter equipped with an output for connection module SOWIE for remote data transmission (see Section 7), which allows use counters:

  • as part of a system for remote data acquisition and processing (ЕverBlu, AnyQuest, M-Bus);
  • as part of a system of monitoring and control of technological processes;
  • as flow meter thermal energy (hot water meters).

1.3 Meter may be installed in wells and flood-prone areas (see item 2.6. and 4.3).

2 MAIN TECHNICAL AND METROLOGICAL CHARACTERISTICS

2.1 Metrological characteristics of the counters correspond to the class In accordance with DSTU 3580-97 when installed in any position.

2.2 cold water Meters Woltex... WE are certified to operate on two nominal costs Qn: normal (N), characteristic of the water meters of a given diameter, and high (G), characteristic of water meters nearest larger diameter (see Table 2-3).

2.3 Technical and metrological characteristics of counters are shown in tables 1-5.

Table 1-Typical performance of water meters Woltex WE.

Characteristics nominal diameter, DN Znaczenia characteristics: mm 50 65 80 100 150 200 250 300 Starting the volume flow Оst* m3/h 0,19 0,22 0,3 0,38 1,0 1,6 3 10 The minimum volume flow Qmin * m3/h 0,35 0,5 0,75 0,9 1,5 2,5 3,5 12 Transition flow, Qt* m3/h 0,4 0,6 1,2 1,5 3 3,5 5 15 Maximum constant volume flow Qmax m3/h 50 80 120 200 500 800 1200 2000 Peak flow (10 min), and QR m3/h 90 200 250 300 700 1000 1500 2500 Pressure loss at Qmax (see figure -2) bar 0,2 0,5 0,55 0,23 0,15 0,12 0,12 0,2 The maximum water temperature °C 50 The maximum excess pressure bar 20 (50 special version)

*Average values

Table 2 - Metrological characteristics of counters modifications WE to account for cold water.

Characteristics nominal diameter, DN Znaczenia characteristics: mm 50 65 80 100 150 200 250 300 Nominal volume flow Qn m3/h 15 25 40 60 150 250 400 600 25 40 60 100 250 400 600 1000 The maximum volume flow, Qmах m3/h 50 80 120 200 500 800 1200 2000 Transition flow, Qt m3/h 3 5 8 12 30 50 80 120 Minimum constant volume flow Qmin m3/h 0,45 0,75 1,2 1,8 4,5 7,5 12 18 The maximum water temperature °C 30 (short 50) Maximum working pressure (excess) bar 20 Capacity roller reading device 99999999 99999999 The price of the pulse output signal l/pulse 10 100 Price minimum pressure scale l 0,2 2

Table 3 - Metrological characteristics of counters modifications WEG, WEN to account for cold water.

Characteristics nominal diameter, DN Znaczenia characteristics: mm 50 65 80 100 150 200 250 300 Nominal volume flow Qn N m3/h 15 25 40 60 150 250 400 600 G 25 40 60 100 250 400 600 1000 The maximum volume flow, Qmах N m3/h 30 50 80 120 300 500 800 1200 G 50 80 120