Heat meter - ultrasonic flow meter Ultraheat 2WR7
Company: | TOV 'Torgovo-promyishlennaya kompaniya 'Tehnoprom' |
Seller: | Sergej Aleksandrovich |
Phones: | +38 (96) 8897777 Show phone |
Address: | Kyiv, Ukraine |
Ultrasonic flow meter ULTRAHEAT 2WR7 is designed to measure
flow in the water heat exchange systems using ultrasound.
Scope
Ultrasonic flow meter ULTRAHEAT 2WR7 is intended for use in
as flow sensor for calculators when taking into account the consumption of heat
or cold. Readings of the flowmeter may
need to play through the optical port. Not suitable for systems with
water-picoline mixtures.
Composition
Ultrasonic flow meter ULTRAHEAT 2WR7 consists of a flow sensor
(full metal version) and attached to the electronic module.
These two components are rigidly interconnected by a cable. Meter
flow is also available in protection IP 65 (standard: IP 54).
Main technical specifications
* No wear due to absence of moving parts.
* Measuring range flow 1:100 according to EN 1434, General 1:1000.
* Battery power 5 or 9 years.
* Optical interface according to EN 61107
* Pulse output
* Registration accumulated monthly values with depth archive 36 months ( removing data via optical interface)
* Self-diagnosis, including diagnosis pollution measuring
channel flow Converter with early warning and
registration start date pollution (removing data through
optical interface)
Operational characteristics
* Working position arbitrary embedding in direct or reverse the pipeline, calm zone of flow are not required.
* Temperature range 10...130°C (heat) from 10 to 50°C (cold). The maximum temperature 150°C for 2000 hours.
Functionality
* The flow measurement.
* Archiving of 36 monthly values (accumulated volume, maximum flow rate and downtime).
* Self-diagnosis, including diagnosis pollution measuring
channel flow Converter with early warning and
check the date of commencement of process contamination.
Interfaces
Ultrasonic flowmeters ULTRAHEAT 2WR7 optical interface according to EN 61107 as standard, such as reading, diagnosis, to work with the program PappaWin or to configure parameters.
Specification standard pulse output:
Type open collector bipolar
Polarity no
Pulse value see on the front panel
The pulse length see on the front panel
The pulse sequence of packets, each 0.5 s in the package
Cable length 2 m
The maximum voltage 30 V
Current 30 mA maximum
Voltage loss Dialekticheskaya strength 500 Вeff (electrically disconnect. )
Other types of pulse outputs OB, OD according to EN 1434 (option on request)
Option OB (EN 1434):
The maximum voltage 30 V
Current 30 mA maximum
Voltage loss of about 1.3 V At 20 mA
Polarity is
Option OD (EN 1434):
The maximum voltage 30 V
The maximum current of 0.5 mA
Loss of voltage Polarity is