Ultrasonic heat meter PolluStat
Company: | TOV 'Torgovo-promyishlennaya kompaniya 'Tehnoprom' |
Seller: | Sergej Aleksandrovich |
Phones: | +38 (96) 8897777 Show phone |
Address: | Kyiv, Ukraine |
Ultrasonic heatmeter PolluStat
Certificate of type approval
measuring technique №UA-M1/1p-1251-2006
The State Register №Have 1703-05
The calibration interval is 4 years
Application
Ultrasonic heat meter PolluStat E is designed to measure spent the amount of heat in otopitelnyh or refrigeration installations in which the heat liquid water. Strong performance (all-metal) flow meter parts with the measurement range 1:200, which is a guarantee of all the changes in consumption (and when the fluctuations of consumption). The image of the measured and recorded data occurs on the LCD display and split up to 4 levels:
-
consumer level spent amount of heat tariff register and instantaneous flow rate
-
archive level - 16 monthly quantities consumed the amount of heat, total, maximum monthly expenses and power
-
service level - the maximum flow rate, power, temperature at the inlet and the outlet, the time interval for calculating the maximum power
-
parametrizations level - set the following values directly on location: primary and secondary address M-BUS, customer number, interval time to calculate the maximum power
Part of the counter heat and thermal resistance Pt 500 or Pt 100 for measuring water temperature in the supply and return the pipelines. Wire temperature sensors resistance can 4-wires to lengthen.
PolluStat E - ultrasonic heat meter for installation in the return pipe (the pipe with the lowest temperature)
PolluStat EX - ultrasonic heat meter for installation in the inlet pipeline (the pipeline with the highest temperature)
Performance
-
Approval in accordance with EN 1434 class 2 (measuring range 1:200)
-
No moving parts in the flow meter parts
-
Installation in horizontal or vertical position
-
Compact heat meter consists of a flow meter, heat meter and temperature sensors resistance
-
The possibility of separating the heat from a flow meter parts
-
The opportunity postoyannoi load consumption of 2 times the qp
-
Temperature range flow meter parts from 5 to 150° allows application in 6/12°C Kladusa equipments with water as the heat environment
-
No sensitivity to impurities 2 - or 4 - wire connection of resistance temperature sensors
-
Two including space for additional equipment module M-BUS module and pulse output without damaging confidential mark
-
Serial interface Mini-Bus
-
Select the image contents
-
Tariff function
Technical characteristics
Ultrasonic heatmeter PolluStat
Certificate of type approval
measuring technique №UA-M1/1p-1251-2006
The State Register №Have 1703-05
The calibration interval is 4 years
Application
Ultrasonic heat meter PolluStat E is designed to measure spent the amount of heat in otopitelnyh or refrigeration installations in which the heat liquid water. Strong performance (all-metal) flow meter parts with the measurement range 1:200, which is a guarantee of all the changes in consumption (and when the fluctuations of consumption). The image of the measured and recorded data occurs on the LCD display and split up to 4 levels:
-
consumer level spent amount of heat tariff register and instantaneous flow rate
-
archive level - 16 monthly quantities consumed the amount of heat, total, maximum monthly expenses and power
-
service level - the maximum flow rate, power, temperature at the inlet and the outlet, the time interval for calculating the maximum power
-
parametrizations level - set the following values directly on location: primary and secondary address M-BUS, customer number, interval time to calculate the maximum power
Part of the counter heat and thermal resistance Pt 500 or Pt 100 for measuring water temperature in the supply and return the pipelines. Wire temperature sensors resistance can 4-wires to lengthen.
PolluStat E - ultrasonic heat meter for installation in the return pipe (the pipe with the lowest temperature)
PolluStat EX - ultrasonic heat meter for installation in the inlet pipeline (the pipeline with the highest temperature