Ultrasonic heat meter PolluStat

Offer type: salePublished: 01.03.2015
Company:TOV 'Torgovo-promyishlennaya kompaniya 'Tehnoprom'
Seller:Sergej Aleksandrovich
Phones:
Show phone
Write a message
Address:Kyiv, Ukraine

Ultrasonic heatmeter PolluStat

performance with ultrasonic flow meter PolluFlow

Certificate of type approval
measuring technique №UA-M1/1p-1251-2006
The State Register №Have 1703-05
The calibration interval is 4 years

Application

Ultrasonic heat meter PolluStat E is designed to measure spent the amount of heat in otopitelnyh or refrigeration installations in which the heat liquid water. Strong performance (all-metal) flow meter parts with the measurement range 1:200, which is a guarantee of all the changes in consumption (and when the fluctuations of consumption). The image of the measured and recorded data occurs on the LCD display and split up to 4 levels:

  • consumer level spent amount of heat tariff register and instantaneous flow rate
  • archive level - 16 monthly quantities consumed the amount of heat, total, maximum monthly expenses and power
  • service level - the maximum flow rate, power, temperature at the inlet and the outlet, the time interval for calculating the maximum power
  • parametrizations level - set the following values directly on location: primary and secondary address M-BUS, customer number, interval time to calculate the maximum power
The design of the heat meter allows separate installation rachadalai and heat. The maximum distance at separate installation of 3 meters.
Part of the counter heat and thermal resistance Pt 500 or Pt 100 for measuring water temperature in the supply and return the pipelines. Wire temperature sensors resistance can 4-wires to lengthen.

PolluStat E - ultrasonic heat meter for installation in the return pipe (the pipe with the lowest temperature)
PolluStat EX - ultrasonic heat meter for installation in the inlet pipeline (the pipeline with the highest temperature)

Performance
  • Approval in accordance with EN 1434 class 2 (measuring range 1:200)
  • No moving parts in the flow meter parts
  • Installation in horizontal or vertical position
  • Compact heat meter consists of a flow meter, heat meter and temperature sensors resistance
  • The possibility of separating the heat from a flow meter parts
  • The opportunity postoyannoi load consumption of 2 times the qp
  • Temperature range flow meter parts from 5 to 150° allows application in 6/12°C Kladusa equipments with water as the heat environment
  • No sensitivity to impurities 2 - or 4 - wire connection of resistance temperature sensors
  • Two including space for additional equipment module M-BUS module and pulse output without damaging confidential mark
  • Serial interface Mini-Bus
  • Select the image contents
  • Tariff function

Technical characteristics


Ultrasonic heat meter PolluStat
click on photo to enlarge

Ultrasonic heatmeter PolluStat

performance with ultrasonic flow meter PolluFlow

Certificate of type approval
measuring technique №UA-M1/1p-1251-2006
The State Register №Have 1703-05
The calibration interval is 4 years

Application

Ultrasonic heat meter PolluStat E is designed to measure spent the amount of heat in otopitelnyh or refrigeration installations in which the heat liquid water. Strong performance (all-metal) flow meter parts with the measurement range 1:200, which is a guarantee of all the changes in consumption (and when the fluctuations of consumption). The image of the measured and recorded data occurs on the LCD display and split up to 4 levels:

  • consumer level spent amount of heat tariff register and instantaneous flow rate
  • archive level - 16 monthly quantities consumed the amount of heat, total, maximum monthly expenses and power
  • service level - the maximum flow rate, power, temperature at the inlet and the outlet, the time interval for calculating the maximum power
  • parametrizations level - set the following values directly on location: primary and secondary address M-BUS, customer number, interval time to calculate the maximum power
The design of the heat meter allows separate installation rachadalai and heat. The maximum distance at separate installation of 3 meters.
Part of the counter heat and thermal resistance Pt 500 or Pt 100 for measuring water temperature in the supply and return the pipelines. Wire temperature sensors resistance can 4-wires to lengthen.

PolluStat E - ultrasonic heat meter for installation in the return pipe (the pipe with the lowest temperature)
PolluStat EX - ultrasonic heat meter for installation in the inlet pipeline (the pipeline with the highest temperature