Bizator  /  Adverts  /  equipment and materials  /  industrial equipment  /  laboratory equipment

Sell vibrohammer VSHV 003 M2

Offer type: salePublished: 28.02.2015
Price:negotiated
Seller:Zubko Sergej
Phones:
Show phone
Write a message
Address:Ukraine, Luhans'ka Oblast', Luhansk
Measuring noise and vibration VSHV-003-M2 (VSHV003M2, VSHV 003 M2, VSV-M2, VSV M2, VSHV-003M2, VSHV 003M2).
Is the recommended list of equipment for service stations for technical inspection of vehicles of 2011.
Sound level meter VSHV-003-M2 is designed to measure sound pressure level in the range from 2 Hz to 18kHz and octave bands in the frequency range from 2 Hz to 8 kHz in the diffusion and the free fields; sound level with frequency characteristics a, b, C; average quadratic values of velocity and acceleration.
Sound level VSHV-003-M2 can be useful for research and testing of machines and mechanisms (in particular at the technical inspection of vehicles); in industry and residential quarters for the protection of health, in the control and development of quality products.
I corresponds to accuracy class according to GOST 17187-81 (ST SEV 1351-78, IEC 651).
 
Technical characteristics of the instrument gauges noise and vibration VSHV-003-M2
 
Parameterdatabase operation:
- ambient temperature
- relative humidity not more than
from -10 º C to +50°C
80% at 20°Solosa device frequency measuring noise and vibration VSHV-003-M2:
- measurement, vibration
- sound pressure level of characterization of LIN
 

from 1 Hz to 10000 Hz
from 2 Hz to Hz
Frequency of characteristica, b, C, Linganamakki the range of measurement of vibration parameters:
- acceleration
- vibration
- sound level (relative to 20 µpa)
3·m/S2 to m/S2
3·102mm/s to 5·104mm/s
from 22dB to BEA measurement error of the instrument sound level meter VSHV-003-M2:
- vibration parameters
noise
 

±10%
±0,7 dB
Power:
- voltage AC
- the total voltage of the battery pack
220V±22V
from 5V to 7.5 Upotrebljaemaja instrument measuring noise and vibration VSHV-003-M2 power:
- when powered by AC, not more than
- when powered by the battery pack, not more than
 

5.0 V∙A
1.0∙A
Filters octave with a geometric mean catatonic; 2; 4 Hz; 8gts; 16hz; 31,5 Hz; 63Hz; 125 Hz; 250Hz; 500Hz, 1000Hz; 2000Hz; 4000Hz; art dimensions:
- measuring instrument
- preamp VPM-101
- capsule condenser microphone M101
Converter LTO-3-M1
Converter LTO-4-M1
- power supply 220V
screen
Him
143хØ26,5mm
19хØ23,77mm
H,Hm
H,5x18,5mm
Him
49хØ56ммМасса device measuring noise and vibration VSHV-003-M2:
- measuring instrument
- preamp VPM-101
- capsule condenser microphone M101
Converter LTO-3-M1
Converter LTO-4-M1
- power supply 220V
screen
 

4.5 kg
0,556 kg
0,031 kg
0.05 kg
0,013 kg
0.7 kg
0,014 kg
The average time to failure, not menee chaseside service life of the device measuring noise and vibration VSHV-003-M2, not menee years