Elektrozapalom pulse EEZ-1
Seller: | Aleksandr |
Phones: | 0507379739 Show phone |
Address: | Ukraine, Chernihivs'ka Oblast', Chernihiv |
THE 34-70-009-90
Pulse elektrozapalom (EEZ), which consists of electronic block (EB) and spark plugs (SWS) is part of the gas-pulse cleaning (GMOs) heating surface power boilers water boilers and etc. from external deposits by burning in furnaces solid fuel or fuel oil, as well as heat exchangers working in dust-Laden process gases. The main purpose of the EEZ - the burning of gas mixture in devices of GMOs with discrete variable frequency. The EEZ may be included in remote or automatic control circuit pulse cameras GMOs.
Conditions of use:
- ambient temperature - 0 to +60°C,
- relative humidity at +35°C - 80%,
- altitude above sea level less than 2000 m,
- environment is not explosive, not containing dust (including conductive) in an amount that breaks the DL, as well as corrosive gases and vapors at concentrations that Deplete metals and insulation,
- impact on the supply of impulse noise amplitude, not exceeding double the value of the rated voltage and not longer than 10 μs.
The degree of protection of the EEZ - UR-40 according to GOST 14255-69.
Elektrozapalom pulse EEZ-1
Option
Norm
1
Power supply, AC
In
220(+22-33)
2
Network frequency
Hz
50±1
3
The regulation limits the frequency of impulses, discrete after 5 p.
with
5-30±10%
4
The duration of the discharge
MS
200 (+50-10)
5
The power consumption at discharge, not more than
W
900
6
The signalling voltage on DL
Yes
Yes
8
Weight, not more
kg
1