Bizator  /  Adverts  /  equipment and materials  /  industrial equipment  /  electrical survey units

The detector flammable gas WATCH-

Offer type: salePublished: 01.03.2015
Company:TOV 'Torgovo-promyishlennaya kompaniya 'Tehnoprom'
Seller:Sergej Aleksandrovich
Phones:
Show phone
Write a message
Address:Kyiv, Ukraine

The detector flammable gas WATCH-

The purpose

Stationary gas detectors - gas detectors harmful substances designed for continuous automatic measurement of content one or more components of the gas mixture and issuing alarm when exceeding the maximum permissible concentrations in accordance with GOST 12.1.005-88.

Gases

sulfur dioxide

nitrogen dioxide

oxygen

carbon monoxide

hydrogen sulfide

ammonia

chlorine

Application

The oil, gas, chemical, food and other industries.

Dignity

Microprocessor system information processing and self-diagnostics

Built-in light and sound alarm for each channel

Automatic adjustment of the "zero"

Digital readout device gas concentration

The ability to control external devices

automatic malfunction-free transition to backup power in case of principal

the presence of the current and digital outputs

the ability to simultaneously control MPC harmful gases and dovzryvoopasnyh concentrations of combustible gases.

Completeness
block (BPS) - metal (IP40 - for internal installation) or polycarbonate (IP65 for indoor and outdoor installation)
sensor (PI) - from 1 up to 8 pcs. pcs. (depending on version)- spare parts kit - 1 set.
- set mounting parts - 1 set.
- manual - 1 copy
- test procedure - 1 copy
- passport - 1 copy

Specifications

Measurement ranges:
- ammonia from 0 to 120 mg/m3 or 0 to 1500 mg/m3
- nitrogen dioxide from 0 to 15 mg/m3
- sulphur dioxide from 0 to 120 mg/m3
- carbon monoxide from 0 to about 1. % or from 0 to 120 mg/m3
oxygen from 0 to about 1. % or from 0 to about 30. %
the hydrogen sulfide from 0 to 50 mg/m3
- chlorine from 0 to 5 mg/m3
Limits of basic absolute error (depending on the component being controlled) ±0,06; ±0,8; ±1,25; ±7,5
Operating temperature range from minus 40 to 50 °C
for BPS from 1 to 50 °C
for PIS from minus 40 to plus 50 °C
Output signals:
- management of Executive devices

"dry" contact threshold devices:

  • combined across all channels or 2 groups of channels (BPS IP40)
  • separate for each channel (BPS IP65)
  • relay 2 A, ~220 V
  • current output 0-5, 0-20 or 4-20mA
  • digital output RS232 or RS485 (only in the case IP65).
    Number of measuring channels

1, 2, 4 (BPS IP40)
1, 2, 3, 4, 5 (BPS IP65)
Sound and light alarm automatic
Food

BPS IP40: ~220V 50 Hz
BPS IP65:main ~220V, back In 80-270
Overall dimensions and weight, not more:
- block (depending on version)

HH mm (BPS IP40) /4,0 kg
HH mm (BPS IP65) / 4,0 kg
sensor (depending on version)

HH mm / 0.4 kg
HH mm / 0.4 kg