The detector flammable gas WATCH-
The purpose
Stationary gas detectors - gas detectors harmful substances designed for continuous automatic measurement of content one or more components of the gas mixture and issuing alarm when exceeding the maximum permissible concentrations in accordance with GOST 12.1.005-88.
Gases
sulfur dioxide
nitrogen dioxide
oxygen
carbon monoxide
hydrogen sulfide
ammonia
chlorine
Application
The oil, gas, chemical, food and other industries.
Dignity
Microprocessor system information processing and self-diagnostics
Built-in light and sound alarm for each channel
Automatic adjustment of the "zero"
Digital readout device gas concentration
The ability to control external devices
automatic malfunction-free transition to backup power in case of principal
the presence of the current and digital outputs
the ability to simultaneously control MPC harmful gases and dovzryvoopasnyh concentrations of combustible gases.
Completeness
block (BPS) - metal (IP40 - for internal installation) or polycarbonate (IP65 for indoor and outdoor installation)
sensor (PI) - from 1 up to 8 pcs. pcs. (depending on version)- spare parts kit - 1 set.
- set mounting parts - 1 set.
- manual - 1 copy
- test procedure - 1 copy
- passport - 1 copy
Specifications
Measurement ranges:
- ammonia from 0 to 120 mg/m3 or 0 to 1500 mg/m3
- nitrogen dioxide from 0 to 15 mg/m3
- sulphur dioxide from 0 to 120 mg/m3
- carbon monoxide from 0 to about 1. % or from 0 to 120 mg/m3
oxygen from 0 to about 1. % or from 0 to about 30. %
the hydrogen sulfide from 0 to 50 mg/m3
- chlorine from 0 to 5 mg/m3
Limits of basic absolute error (depending on the component being controlled) ±0,06; ±0,8; ±1,25; ±7,5
Operating temperature range from minus 40 to 50 °C
for BPS from 1 to 50 °C
for PIS from minus 40 to plus 50 °C
Output signals:
- management of Executive devices
"dry" contact threshold devices:
- combined across all channels or 2 groups of channels (BPS IP40)
- separate for each channel (BPS IP65)
- relay 2 A, ~220 V
- current output 0-5, 0-20 or 4-20mA
- digital output RS232 or RS485 (only in the case IP65).
Number of measuring channels
1, 2, 4 (BPS IP40)
1, 2, 3, 4, 5 (BPS IP65)
Sound and light alarm automatic
Food
BPS IP40: ~220V 50 Hz
BPS IP65:main ~220V, back In 80-270
Overall dimensions and weight, not more:
- block (depending on version)
HH mm (BPS IP40) /4,0 kg
HH mm (BPS IP65) / 4,0 kg
sensor (depending on version)
HH mm / 0.4 kg
HH mm / 0.4 kg