CTX-17 Signaling-explosimeter thermochemical CTX-17
Price: | negotiated |
Company: | TOV 'Torgovo-promyishlennaya kompaniya 'Tehnoprom' |
Seller: | Sergej Aleksandrovich |
Phones: | +38 (96) 8897777 Show phone |
Address: | Ukraine, Kyiv |
Scope
Production facilities of the enterprises of chemical, oil and gas and other industries, utilities, boats and floating facilities regulated Maritime Register of shipping.
CTX-17 applied wherever there is a danger of explosion of flammable gases and vapors, namely:
* wells, pits before hot work;
* emptied the containers of fuel;
* boiler ignition boilers on gas fuel;
* in the process of oil production, refining, gas production;
* oil and gas pipelines, filling stations;
* at fuel depots in the ports and railroads, depots, aircraft storage;
* storage tanks for petroleum products, alcohol and other ;
* at stations draining oil from the tanks come in various
transport and racks spillages of petroleum products to consumers;
* pumping stations and other facilities of oil, gas, chemical and
other industries, on the object, supervised by the Sea
The register of shipping.
The purpose
Industrial portable portable automatic
alarms-explosimeter CTX-17 are designed to control
dovzryvoopasnyh concentrations of combustible gases and vapours of flammable liquids and
their entirety in the air and issuing alarm on exceeding
the set concentration.
Dignity
* Wide range of indications: 00,0 of 99.9% LEL;
* Explosion proof, explosion-proof marking-quot;1ExdibsllCT4";
* Diffusion and forced (with nozzle) sampling;
* Digital display the current value of the concentration at the three-digit seven-segment display;
* Self-test in an automatic mode;
* Minimal maintenance, easy operation;
* Two alarm thresholds;
* High metrological characteristics, does not require additional devices to adjust the functional parameters;
* The ability to control remote sensor;
* Access protection settings and critical parameters of an emergency condition.
Description
The detector CTX-17 is an individual portable single continuous unit with light and sound alarm with two alarm thresholds, with convection or forced-controlled environment.
The spatial location of CTX-17 during operation - any.
CTX-17 has two modes of operation: alarm and explosimeter. In the mode detector CTX-17 provides for the issuing light and sound signal Threshold 1 and Threshold 2". Mode explosimeter CTX-17 displays on the digital display the current value of the concentration unit component and provides for the issuing of light and sound signals "Threshold 1" and "Threshold 2".
Optional concentrations of single or separate
(of aggregate) of the controlled components can be represented in
as the volume fraction (metrological certification).
Modification CTX-17
Performance CTX-17 Controlled component Testing component
CTX-17-80 Methane, and the sum of components Methane (CH4)
CTX-17-81 Hydrogen and the combination of components of the Hydrogen (H2)
CTX-17-83 Ethanol (ethyl alcohol) Propane (SN)
CTX-17-84 Propane Propane (SN)
CTX-17-85 n-butane n-butane (n-SN)
CTX-17-86 n-Hexane n-Hexane (n-SN)
CTX-17-87 Gasoline n-Hexane (n-SN)
CTX-17-88 Isobutane Isobutane (i-SN)
CTX-17-90 Methane, and the sum of components Methane (CH4)
CTX-17-91 Hydrogen and the combination of components of the Hydrogen (H2)
The structural design is provided for the embedded block sensitive elements (SE) and the remote sensor.
CTX-17-71, CTX-17-72 can be used on ships and other objects, supervised Maritime Register of shipping.
The CTX-17-90 and CTX-17-91 is the concentration of single or separate
from the set of monitored components are presented in the form of bulk
share in%.
Specifications № Name of indicator Value
1 indications Range CTX-17, % LEL from 0.00 to 99.9
2 measurement Range, % LEL: 0 to 55
3 maximum permissible absolute error, % LEL:
for calibration component
±5
4 Range, which can be set thresholds
the signal concentration on customer demand, % LEL 10 to 45
5 Nominal value of threshold devices, % LEL:
for signal "Threshold 1"
for signal "Threshold 2"
20
40
6, the sound pressure Level on the axis sounder at a distance of 0.3 m, dB, not less than 60
7 warm-up Time, with no more than 20
8 Time signal, with not more than 10
9 Voltage from the built-in rechargeable power source, from 2.1 to 2.8
10 Current consumption CTX-17, mA, not more than 180
11 Time of continuous operation without recharging, h, not less than 10
12 dimensions
13 with a built-in unit SE, mm, not more HH
14 remote sensor, mm, not more than 70 x ∅14,5
15 cable length remote sensor, m 2,0
16 Weight, kg, not more:
with built-in unit
with remote sensor
0,3
0,35
17 the Average time to failure, h, not less than 50000
18 average service life, years, not less than 10
19 Conditions:
ambient temperature and controlled environment, °C
relative humidity at 25 °C, %
atmospheric pressure, mm RT. Art.
from - 40 to + 55
(95±3)
from 630 to 800
Accessories: camera Calibration, rod, key.
By separate order comes nozzle (to force selection samples from hard to reach places), damper (for mechanical protection remote sensor), charger, memory-8 memory-10.