Bizator  /  Adverts  /  equipment and materials  /  power engineering equipment  /  local telephone exchange and complete local telephone exchange

Cabinets low voltage SRN

Offer type: salePublished: 27.02.2015
Price:negotiated
Company:td Elektroschit
Seller:Gurvich Mark Vladlenovich
Phones:
Show phone
Write a message
Address:Russian Federation, Vladimirskaya Oblast', Vladimir

Cabinets low voltage further SRN designed for receipt, distribution and accounting of electric energy, as well as to protect against overloads and short circuit currents in three-phase electrical networks earthed neutral voltage 380/220 V AC frequency 50 Hz .SRN are part of the complete transformer substations booth type (KTP) and the concrete type (MITS), are installed in the compartment distribution low-voltage ( low voltage switchgear) .

Classification SRN

The composition SRN Type apparatus

Compartment introductory unit Switch automatic

Switch

Disconnector

Compartment metering electric energy Meter registration of active energy

Counter accounting reactive power

Counter accounting of active and reactive power

Bay street lighting and heating compartment RUNN

Compartment outgoing lines Switch automatic

Otherwise piece circuit breakers-fuses

The breakers with fuses

From 2 to 10 outgoing lines

Feeder street lighting

 

Design

 

The Cabinet is a horizontally placed teams tires were installed on the switch-disconnector-fuses ("feeders") with a vertical arrangement of phases single connection. Each feeder performs the functions of the disconnector and protection against overloads and short circuits connected to the bottom of the cable line. For nutrition and consumer protection with rated current over 630A use a combination cabinets - module protection of outgoing line circuit breaker.

 

Schema auxiliary connections include:

 

a) measurement of the line voltage between all phases. The control bus bar voltage 0.4 kV by using a voltmeter. Voltmeter connected to the phases through the switch;

b) calculation of electrical energy to the input voltage . The metering electricity is by meter;

C) heating electricity meters. To ensure normal meter operation in winter conditions heated the heaters;

g) automatically enabling and disabling of the heating compartment Low voltage switchgear. Turning on the heaters automatically heat the temperature sensor relay;

d) lighting compartments complete transformer substation kiosk type: working - on voltage 36 In . Lighting lamp included manually household switches;

Protection against short circuits lighting circuits is the fuse from the power input and fuse with side 36 C.

e) street lighting, which turns on and off by the signal built-in photocell. T./F. 4922-305368 ;8-903-6471471