Bizator  /  Adverts  /  equipment and materials  /  industrial equipment  /  electrical survey units

2in1 Thermostat-timer UDS-220.R Ti999 10x10 (10 modes temperature, 10 modes of time) DIN

Offer type: salePublished: 01.03.2015
Price:364 UAH45 $
Company:UDS-device
Seller:UDS device
Phones:
Show phone
Write a message
Address:Ukraine, Kharkivs'ka Oblast', Kharkiv
2in1 Thermostat-timer UDS-220.R PLAST TP999 10x10 DIN (10 modes temperature, 10 modes of time) is intended for automatic control of the temperature of the object (the two-position control) at a specified time. The unit is designed for use with thermocouples type THA (K), TXK (L). Thermocouple THA (K) (up to +800C) in the kit. PRICE: UAH 364 Price:45$ Delivery in any point of Ukraine and CIS countries. so +38 0637138877 +38 (057)759-42-42 E-mail: cifropribor@yandex.ru Website: http://cifropribor.ya.ru Specifications: Power consumption: less than 5W Voltage: 220V AC Weight: not more than 0.3 kg The type of thermocouple: TXA(K), TXK (L) The range of measurement and control: +4...+ 999°C (K) + 600°C (L) The job step temperature 1°C Time mode 0...999 minutes The number of steps time: 10 The basic reduced error of measurement: 5 % Measurement time: 1s Period management: 1C The number of digits of the indicator: 3 Device load control: electromagnetic relay load not more than 5A (1100 Watts) Programming the device: The device has two modes of OPERATION and TUNING. Mode: In run mode the instrument measures the current temperature, displays it on the display and makes the regulation of the given tempera-tours. If the operation of the device, more zero values, after the first output of the measured temperature to a predetermined included a countdown of time (current value can be viewed by pressing the UP button). To achieve a time value equal to zero, the load is switched off, the indicator will appear to the End. The transition mode is done by pressing DOWN. Mode SETTING: setting the new value adjustable temperature: Click on the ENTER button. When the indicator tpX (X is the number of stages) the button should be released. The indicator will show the temperature regulation in flashing mode. The temperature setting by pressing the UP and DOWN buttons. Fixing the value of the parameter like pressing and holding the button ENTER. installing a new time values: Click on the ENTER button. When appears on the display tiX (X is the number of stages), the ENTER button must be released. To change the selected parameter, press the UP or DOWN key. The indicator will show the time of the device (in minutes) after the first output of the measured temperature to the set point. Adjustment range 0...999. The setting by pressing the UP and DOWN buttons. Fixing the value of the parameter is the ENTER button . setting the new value hysteresis: Click on the ENTER button. When appears on the display GIS the ENTER button must be released. To change the selected parameter, press the UP or DOWN key. The indicator will show the temperature hysteresis (temperature load shed = (t*C ) - (GIS) is selected experimentally) in flashing mode. The temperature setting by pressing the UP and DOWN buttons. Fixing the value of the parameter is the ENTER button. installation type thermocouple: Click on the ENTER button. When appears on the display type the ENTER button must be released. To change the selected parameter, press the UP or DOWN key. The indicator will show the number of type thermocouple. The number 0 corresponds to the type TXA(K), 1 type TXK (L). Installation type thermocouple is made by pressing the UP and DOWN buttons. Fixing the value of the parameter is the ENTER button. setting the new value of gain: Click on the ENTER button. When appears on the display CoF the ENTER button must be released. To change the selected parameter, press the UP or DOWN key. The indicator will show the gain of the amplifier, thermocouple (default - 83.6). When you change the settings of the thermocouple (aging, oxidation), you may have to adjust the gain of the amplifier thermocouple. Setting the gain is adjusted by pressing the UP and DOWN buttons. Adjustment range 50-250. Fixing the value of the parameter is the ENTER button. install the new calibration values: Click on the ENTER button. When appears on the display CAL the ENTER button must be released. To change the selected parameter, press the UP or DOWN key. The indicator will show the calibration value of temperature readings. If the temperature of the thermostat does not coincide with the reference thermometer - add (reduce) the value of this parameter on the magnitude of the mismatch with the reference thermometer. Adjustment range -60...+60. The setting by pressing the UP and DOWN buttons. Fixing the value of the parameter is the ENTER button. Mode SETTING - if within 3 seconds didn't button the device enters the operating mode. When the breakage of the thermocouple and the temperature is less than +2 degrees on the display device appears - obr (open circuit) and the heating will be disabled.